User's Manual
Innovator CU0TD-1/CU0RD-1 – CU4TD/CU4RD 8VSB ATSC Modulator
ATSC Transmitter/Regenerative Translator
Instruction Manual, Rev. 2 54
Item Selection
NLP Method Legacy, RLS, Regression
Used to select Pre-correction algorithm.
NLP Cycles Range: 1 .. 10
Ratio of NLP cycles to LP cycles. “X” number of NLP
cycles will run before one LP cycle is run.
Precorrection Stop, Run
Used to Run or Stop the cycles (adaptation processes).
Note: Pre-correction is not disabled when the cycles are
stopped.
Reset Precorector OFF, ON
Used to clear the NLP and LP coefficients.
Bypass To Host OFF, ON
Parameter is only set to ON if the Digital Pre-corrector is
controlled using the PC GUI application.
Adaptive NLP Profile Name Up to 35 alphanumeric characters
Adaptive NLP Profile Number Range: 1 .. 10
Save Adaptive NLP Profile OFF, ON
Set to ON, to save curve to memory. Profile name and
number should be entered before saving.
Adaptive LP Profile Name Up to 35 alphanumeric characters
Adaptive LP Profile Number Range: 1 .. 10
Save Adaptive LP Profile OFF, ON
Set to ON, to save curve to memory. Profile name and
number should be entered before saving.
Table 14: Digital Precorrector Parameters
Note: If the user would like to use the Adaptive Pre-corrector PC GUI, several
parameters must be configured via the Web GUI (or CLI) before communication between
the modulator and Adaptive Pre-corrector GUI can be established. The user must set
the “Bypass To Host” parameter to “ON” and the “Precorrection” parameter to “Stop”.
UART Baudrate
Note: The UART Baudrate page is reserved for factory configuration and should
not be modified by the user.
Comment [M1]: Added text