Note: If the user has saved a profile (curve) to memory and decides to stop the
Adaptive Pre-correction process, the user should navigate to the Non-linear and/or
Linear Pre-corrector pages and select the desired profile from the pull-down menu and
ensure that the state is set to β€œON”. This will ensure that Non-linear and/or Linear Pre-
correction is enabled following a modulator reset and that the correct profile (curve) is
loaded.
Figure 21: Digital Precorrector Configuration
The available parameters are:
Item Selection
1PPS Offset Range: 0.0 .. 10000000.0 usec
Used to offset the cycle start time, relative to the 1PPS
reference signal.
Mode Single Operation, Adaptive
Adaptive mode must be selected for continuous
operation.
NLP/LP Selection NLP, LP, NLP/LP
Used to determine which cycles (adaptation processes)
will be run.