User's Manual

Innovator CU0TD-1/CU0RD-1 – CU4TD/CU4RD Unpacking, Installation &
ATSC Transmitter/Regenerative Translator Maintenance
Instruction Manual, Rev. 2 30
Remote Signal
Name
Pin
Designation
Signal Type Description
Normally or has a Fault. Not available in
dual exciter systems.
(Low = OK : Floating = Fault)
Report Operate
Status
J12-14
Discrete Open Collector Output. –
Indicates whether system is in Operate
or Standby. Not available in dual exciter
systems.
(Low = Operate : Floating = Standby)
Status
Ground J12-15
Ground. Not Available in dual exciter
systems. Normally jumpered to J12-5.
HPA Input and Output Connections
Figure 4: Amplifier Rear Panel Connectors
NOTE: Some amplifier drawers only have a CB1 circuit breaker.
Port Type Function Impedance
J1 N RF Input: On Channel RF from CX driver drawer 50Ω
J2
7/16”
(1.1cm)
Din
RF Output: On Channel RF Output 50Ω
J3 IEC AC Input: AC input connection to 230VAC Source N/A
J4 9 Pos D
Remote: Amplifier Control Interface
(Connects to J11 on the exciter/driver drawer)
N/A
J5 RJ-45 Serial data N/A
J8
Front
Panel
BNC
RF Sample: Output Sample from Combiner thru
Control Board. In a CU500, the sample level is
approximately 70dB down from the output power
level of the drawer.
50Ω
Table 5: Amplifier Connectors
J
1
J
3
J
4
J
2
CB1
CB
2
J5