User's Manual
Innovator CU0TD-1/CU0RD-1 – CU4TD/CU4RD ATSC Initial On Site
Transmitter/Regenerative Translator Turn On Procedure
Instruction Manual, Rev. 2 97
Figure 54.1.5: Chassis Values External Amplifier Fault Number Set-Up Screen
1 2
This screen allows the user to set the number of faults that are allowed before
the external amplifier is disabled. NOTE: Only used with external amplifiers
are in the system.
Screen 1: If One Fault is selected and a fault occurs in an external amplifier,
the entire transmitter is muted and the faulted external amplifier is latched
off. The transmitter is then unmuted and any external amplifiers (fully or
partially operational) are enabled.
Screen 2: If Three Fault is selected and a fault occurs in an external
amplifier, the entire transmitter is muted and unmuted three times before the
faulted external amplifier is latched off.
NOTE: Faulted amplifier sections are re-enabled when latched faults are
cleared in the event log. See Table 9.1 for more information on clearing the
logs.
Figure 54.1.6: Chassis Values IF Processor Selection Screen
This screen allows the user to select that the system has an IF Processor.
Figure 54.1.7: Chassis Values Downconverter Selection Screen
This screen allows the user to select that the system has a Downconverter.
Figure 54.1.8: Chassis Values Amplifier Power Supply Voltage Screen
This screen allows the user to select the Power Supply Voltage.
Figure 54.1.9: Chassis Values Forward Power Fault Adjust Screen
This screen allows the operator to configure a forward power fault threshold
setting. When the exciter is enabled for at least a few seconds and the
system forward power is not greater than or equal to this setting, a fault is
indicated on the status LED and also on the remote fault indicator pin.
Figure 54.1.10: Chassis Values number of Amplifiers in System Screen
This screen indicates the number of external amplifier drawers in the system.
By selecting the enter key, the system will scan to find the number of
external amplifier drawers.
NOTE: Do not change this screen without first consulting with UBS-Axcera.