User's Manual Part 2
1
1
2
2
3
3
4
4
5
5
6
6
D D
C C
B B
A A
REV. DATE DESCRIPTION ECO# APPROVED
Connector 3 pin
1 1
2 2
3 3
CON1
11913R
GND
RFI POWER LINE FILTER
1 3
G
2 4
FILTER
FL1
80071
QTY
NN
UBS Number
MFG N#MFG
Description
J1-3
J1-1
GND
75088R
POWER SUPPLY, 60W, 5V,12V
J1-4
J1-5
J1-1
J1-2
TP1
57662-01
Power Supply PCA
L1
L1
L2(N)
J1-4
J1-5
J1-1
J1-2
TP1
57662-01
Power Supply PCA
L1
L1
75205R
POWER SUPPLY, 30VDC, 1600W
75205R
POWER SUPPLY, 30VDC, 1600W
J10
J10
1
2
93024R
3081 BL005
Alpha Wire
10 AWG 600W PVC Blue
3
3
4
93476 9912 189
BELDEN
12AWG STR PVC 600V 105º Yel-Green
5
5
93019
9912 013
BELDEN
12AWG STR PVC 600V 105ó D BLUE
4
6
QTY
NN
UBS Number
MFG N#MFG
Description
7
93023R
3081 BR005
10 AWG 600W PVC Brown
3
8
93018
9912 001
BELDEN
12AWG STR PVC 600V 105º BROWN
4
9
10
11
L1
L2
GND (N)
277VAC, 30A, 2-pole, magn. circ.brk
1
2
3
4
CB1
80197R
208 AC 2phase 30A
10608R
26-03-4030
MOLEX
.156" Pitch Crimp Terminal Housing 3pos
1
11538R
09-91-0500
MOLEX
.156" Pitch Crimp Terminal Housing 5pos
2
UBS # 11538R
UBS # 10608R
UBS # 10658R
UBS # 10658R
10658R
08-52-0072
MOLEX
.156" Pitch Crimp Terminal,Female
13
16102R
2210.0
Altech Corporation
Ferrule Insulated Std 10AWG Black
2
16101R
2402.0
Altech Corporation
Ferrule Insulated Std 12AWG Gray
4
92795
9918 013
BELDEN
18AWG STR PVC 300V 105º D. Blue
1
L2(N)
L2(N)
L2(N)
12
Back Plate
10090R
19067-0008
MOLEX
Ring Terminal1/4" for 8AWG Wire,Red
5
B
C
B
A
UBS # 92795
UBS # 93018
92794R
9918 001
BELDEN
18AWG STR PVC 300V 105º BROWN
1
13
Title
Document Number
Rev
DATE
Sheet of
Drawn by:
APPROVALS
1
B
4
400W L-Band HPA Wiring AC Diagram
05
59175-02-D01
05/15/2013
Approved by:
Size
400 Spinnaker Way
Vaughan, Ontario,
Canada, L4K 5Y9
Tel: (905) 669-8533
Checked by:
Kosta Bor
UBS # 93024R
UBS # 93023R
GND
GND
Alpha Wire
UBS # 92794R
UBS # 93019
16423R
1
2
TB L1
1
2
1
2
1
2
1
2
16150R
1
2
TB GND
1
2
1
2
16423R
1
2
TB L1
16423R
CTS4U-N
Altech Corporation
TERMINAL BLOCK 35A, DIN RAIL
6
14
16150R
CGT4U
TERMINAL BLOCK, 25A, DIN rail , GND
3
15
Altech Corporation
16321R
CTS2.5U-N
TERMINAL BLOCK, DIN RAIL
3
16
Altech Corporation
86185R
CTS2.5U-N/R
TERMINAL BLOCK, DIN RAIL, RED
3
17
Altech Corporation
86186R
CTS2.5U-N/W
TERMINAL BLOCK, DIN RAIL, White
3
18
Altech Corporation
3
22/07/2013
Changed copnnection HPA to Current Sense
4
24/07/2013
Removed connection 12VDC from Current Sense
2
26/06/2013
Removed small cooling fan 30VDC
TB 1
To TB 2-19
Note 1:
Recommended Hand Crimp Tool - 0638117500 for 0638117500 pins
Recommended Hand Crimp Tool - 1212045 for ferrules
Recommended Hand Crimp Tool - MAC 2210 for ring terminals
5
07/31/2013
Changed terminal connection
PICB101
PICB102
PICB103
PICB104
COCB1
PICON101
PICON102
PICON103
COCON1
PIFL101
PIFL102
PIFL103
PIFL104
PIFL10G
COFL1
PITB?01PITB?02
COTB?
PITB?01PITB?02
PITB?01PITB?02
PITB?01PITB?02
PITB?01PITB?02
PITB?01PITB?02
PITB GND01 PITB GND02
COTB GND
PITB L101 PITB L102
COTB L1
PICON103
PIFL10G
PITB?01
PICB101
PICON101
PICB102
PICON102
PICB103
PIFL101
PICB104
PIFL102
PICON101
PICON102
PICON103
PIFL103
PITB L101
PIFL104
PITB L101
PITB?01
PITB?01
PITB?01
PITB?01
PITB?01
PITB?02
PITB?02
PITB?02
PITB?02
PITB?02
PITB?02
PITB GND01 PITB GND02
PITB L102
PITB L102