10.6.9 HPA Current Misbalance Warning
HPA Current Misbalance Warning - set
when the lowest current (A) reading on one of the
power modules is less than 20% of the highest current (A) reading on one of the power
modules.
NOTE: The maximum output power level of the HPA will be limited to 53 dBm if a HPA
Current Misbalance Warning alarm occurs. The Web-GUI interface has no control over this
action.
• If the output power level is > 53 dBm, it will be automatically reduced to 53 dBm.
• If the output power level is < 53 dBm, no reduction will occur.
10.6.10 HPA Current Misbalance Fault
Note: HPA
Current Misbalance Fault is not implemented at this point in time.
10.6.11 Pre-Driver Current Fault
Pre-Driver
Current Fault (Critical)
5.0 A
Pre-Driver Current Fault – set when the pre-driver current reaches 5.0 A.
NOTE: Automatic HPA shutdown is initiated by the HPA when the critical levels are reached
and a HPA Failure alarm is raised. The Web-GUI interface has no control over this action.
10.6.12 Driver Current Fault
Dri
ver Current Fault (Critical)
7.0 A
Driver Current Fault – set when the driver current reaches 7.0 A.
NOTE: Automatic HPA shutdown is initiated by the HPA when the critical levels are reached
and a HPA Failure alarm is raised. The Web-GUI interface has no control over this action.
10.6.13 Power Module 1 Current Fault
Power
Module 1 Current Fault (Critical)
14.0 A
Power Module 1 Current Fault – set when the power module 1 current reaches 14.0 A.
NOTE: Automatic HPA shutdown is initiated by the HPA when the critical levels are reached
and a HPA Failure alarm is raised. The Web-GUI interface has no control over this action.