User's Manual Part 2
CL1TC-4 400W DVB-H Transmitter Alarms
Product Manual, Rev. 1 132
10.5.18 IP Input Column FEC Error
IP Input Column
Fec Error - set when the IP input column FEC packet format is incorrect.
10.5.19 IP Input Row FEC Error
IP Input Ro
w Fec Error - set when the IP input row FEC packet format is incorrect.
10.5.20 Upconverter Communication Error
Up Co
nverter Communication Error - set when communications with the Upconverter has
failed.
Note: The alarm is hard coded to mute the modulator in SFN and MFN mode. Transmission
is restored when the alarm is cleared.
Note: The Alarm Properties -> Mute On Alarm setting for this alarm should always be set to
OFF.
10.5.21 Upconverter Unlock
Up C
onverter Unlock - set when the internal Voltage Controlled Oscillator (VCO) is unlocked.
Note: The alarm is hard coded to mute the modulator in SFN and MFN mode. Transmission
is restored when the alarm is cleared.
Note: The Alarm Properties -> Mute On Alarm setting for this alarm should always be set to
OFF.
10.5.22 Upconverter Level Set Failure
Up C
onverter Level Set Failure - set when the Up Converter output level fails to meet the
targeted value +/- 1 dB.
Note: The alarm is hard coded to mute the modulator in SFN and MFN mode. Transmission
is restored when the alarm is cleared.
Note: The Alarm Properties -> Mute On Alarm setting for this alarm should always be set to
OFF.