User's Manual Part 2
CL1TC-4 400W DVB-H Transmitter Modulator Front Panel
Product Manual, Rev. 1 119
To select a specific alarm to set its properties in other menus the user must first set the
Alarm Index value in the Alarm Index sub-menu screen. Upon entering the Alarm Index
menu the user will see:
----------------------------------------
Alarm Index = 0
[ Modulator Restarted] Heartbeat ...
----------------------------------------
The Alarm Index menu lists all 66 alarms available in the system, with index values from 0
to 65. The full list of alarms available can be found in Table 10-1
.
To select a specific alarm to set its properties, scroll through this list using the left e and
right f button until the desired alarm is enclosed in square brackets and press EXECUTE.
The Alarm Index value will be updated to match this alarm. For example, Modulator
Restarted is Alarm Index 0, Heartbeat is Alarm Index 1, and so on. In the other menus the
name of the alarm being configured will be displayed. For example, if Heartbeat is selected
and the user navigates to the Alarm Severity Level menu the following will be displayed:
----------------------------------------
Heartbeat Alarm Severity Level = Inform
[Informative] Critical Warning
----------------------------------------
8.8.2 Config
x
External Voltage Alarm Setting
----------------------------------------
Alarms, External Voltage Alarm Setting
<VOLTAGE1 TRIGGER POLARITY> Voltage1 ...
----------------------------------------
For Voltage1 through Voltage8 the user can set the following:
Item Selection
Voltage Trigger Polarity <, >
Voltage Trigger Threshold Range: 0.00 .. 10.00
8.8.3 Alarms
x
Log Management
----------------------------------------
Alarms, Log Management
<CLEAR ALARM LOG> Logs Display In Rev...
----------------------------------------
Shortcut: To directly reach this menu Press EXECUTE from Status Display e.
The options are:
Item Option
Clear Alarm Log No, Yes
Logs Display in Reverse No, Yes
Log To Display Transient Log, Alarm Log