User's Manual Part 2
CL1TC-4 400W DVB-H Transmitter WEB Interface
Product Manual, Rev. 1 75
For each alarm, the user can set the following:
Item Option
Alarm Enabled OFF, ON
Used to control whether the selected alarm will be
displayed (ON) or ignored (OFF).
Trap Notification on Alarm OFF, ON
Used to control whether the selected alarm will
produce a SNMP trap notification.
Integration Time 0 to 360 sec
Length of time an alarm condition is present before
the alarm is declared.
Mute on Alarm OFF, ON
Used to control whether the selected alarm will mute
the transmitter output.
Relay on Alarm OFF, ON
Used to control whether the selected alarm will active
the first alarm relay.
Second Relay on Alarm OFF, ON
Used to control whether the selected alarm will active
the second alarm relay.
Alarm Severity Level Critical, Warning, Informative, Cleared
Table 6-12 Alarm Properties Parameters