User's Manual Part 2

CL1TC-4 400W DVB-H Transmitter Modulator Front Panel
Product Manual, Rev. 1 106
EXECUTE Completes editing.
Note 1: If a configurable numeric item has a minimum and/or maximum value,
the user cannot modify the value below the minimum or above the maximum.
Note 2: Incrementing one character above ‘9’ will change this character to ‘0’ and
will increment the next character to the left by one (“carry-on digit”). Similarly,
decrementing one character below ‘0’ will change this character to ‘9’ and
decrement the next character to the left by one.
8.2.2.3 Editing a Text Value
----------------------------------------
Web Password
admin
----------------------------------------
(the character ‘a’ alternates between ‘a’ and ‘_’ at approximately 2 Hz)
The current text string is shown as the editable value. The characters A..Z, a..z, 0..9, -
(minus), _(underscore) and “ “(space) are all supported.
Navigating:
w Positions cursor on previous character.
8 Positions cursor on next character.
6 Decrements the value of the highlighted character in a circular manner.
5 Increments the value of the highlighted character in a circular manner.
EXECUTE Completes editing.
8.2.2.4 Saving Changes
T
o save changes to a menu item press the EXECUTE button. The following display will
appear:
----------------------------------------
Save = EXECUTE, Cancel = other keys
----------------------------------------
Press the EXECUTE button again to save the change or any other button to cancel. After a
short period of time with no input, the operation is cancelled automatically and the display
reverts to the menu directly above the menu just visited.