User's Manual Part 2
CL1TC-4 400W DVB-H Transmitter CLI
Product Manual, Rev. 1 91
7.5 CLI Menu System
The
CLI contains a three level menu system where parameters can be viewed and changed.
7.5.1 Navigation
E
ach menu has been assigned a numeric value for navigation purposes. To navigate
through the CLI menu system, enter the number assigned to the desired menu. Depending
on the menu accessed, the user may have the option to enter a sub-menu, or change a
system parameter.
The following menu prompts are available for navigation and for changing system
parameters:
• Enter Selection – allows the user to change menus or exit the CLI
• Enter New Value – allows the user to change a system parameter
At the “Enter Selection” prompt, the user may also use the following keys to navigate or
exit the CLI menu system:
• r – return to the previous menu
• e – exit the CLI
If the user accesses the “Enter New Value” prompt by mistake or decides that they do not
want to change a parameter, the prompt can be exited without making a parameter change.
Simply clear all alphanumeric parameters and press enter. See the following example
below:
Identification
1. Site Name
2. Site ID
r. Return to previous menu
e. Exit CLI
Enter selection : 2 Site ID
Current Value:
Enter New value: No Changes
7.5.2 Parameter Values
In some cas
es, such as entering the Guard Interval or Code Rate, the selectable parameters
have been assigned a numeric value. This allows the user to change the parameter by
simply entering the number assigned to a different parameter. In other cases, such as
entering the transmitter IP address or Site Information, the user can enter a range of
alphanumeric characters.
All parameter changes are made at the “Enter New Value” prompt.
Enter selection : 6 RF Output Frequency
Current Value: 1670000000 Hz
Range: 1670000000 .. 1675000000
Enter New value: