User's Manual
Innovator CHV400BTD ATSC Transmitter Initial On Site
Turn On Procedure
Technical Manual, Rev. 0 32
Table 11.1.2: Chassis Values Model Number Set Up Screen (BTD/BRD)
This screen allows the set up of the Model Number of the
transmitter/regenerative translator. This causes the system to access the
proper parameters to be displayed on the LCD screens. NOTE: Do not change
this screen without first consulting with Axcera.
Table 11.1.3: Chassis Values Jump to Menu on Fault Set Up Screen (BTD/BRD)
This screen allows the user to select if the system will change the display
automatically. When ON is selected, the screen indicating the faulted condition
is displayed when the fault, event, occurs.
Table 11.1.4: Chassis Values Latch On an Input Fault Set Up Screen (BTD/BRD)
This screen allows the user to select that the system, by selecting ON, will latch
the input fault if it occurs, then if the input returns the fault will still register.
Table 11.1.5: Chassis Values IF Processor Selection Screen (BTD/BRD)
This screen allows the user to select that the system has an IF Processor.
Table 11.1.6: Chassis Values Downconverter Selection Screen (BTD/BRD)
This screen allows the user to select that the system has a Downconverter.
Table 11.1.7: Chassis Values Amplifier Power Supply Voltage Screen (BTD/BRD)
This screen allows the user to select the Power Supply Voltage.
Table 11.1.8: Chassis Values number of Amplifiers in System Screen
(BTD/BRD)
This screen indicates the number of external amplifier trays in the system. By
selecting the enter key, the system will scan to find the number of external
amplifier trays. NOTE: Do not change this screen without first consulting with
Axcera.
Table 11.1.9: Chassis Values Ethernet Option Set Up Screen (BTD/BRD)
Only displayed if Ethernet Controller is not present in your system.