User's Manual

Innovator CHV400BTD ATSC Transmitter Unpacking and Installation
Technical Manual, Rev. 0 14
CHV1000B 1000 Watts 5100 Watts 230 VAC 22.2 Amps to the Cabinet
CHV1500B 1500 Watts 7200 Watts 230 VAC 31.3 Amps to the Cabinet
CHV2000B 2000 Watts 10000 Watts 230 VAC 43.5 Amps to the Cabinet
CHV3000B 3000 Watts 14700 Watts 230 VAC 63.9 Amps to the Cabinet
Input and Output Connections
The input and output connections to the system are made to the jacks mounted on the rear
panels of the CHV200B systems, the drivers for the CVH400B and high power systems, and
to the 500 Watt, 750 Watt and 1000 Watt amplifier trays. The CHV200B systems and the
drivers for the CVH400B and higher power systems accept an On Channel RF signal (BRD)
or a SMPTE-310 (BTD) input and output a digital RF ON Channel signal. Refer to Figure 3
and to Table 2 that follow for the locations and information on the jacks and connectors.
Figure 3: Rear View CHV200B and the driver for the CHV400B & higher power systems
Table 2: Connections for the CHV200B and the driver for the CHV400B & higher
power Systems
Port Type Function Impedance
J1 BNC
Input A: On Channel RF Input (BRD) –78 to –8 dBm or
SMPTE-310 Input (BTD)
50 Ohms
J4 BNC SMPTE-310 Output (BRD Only) Normally jumpered to J5 50 Ohms
J5 BNC SMPTE-310 Input (BRD Only) Normally jumpered to J4 50 Ohms
J6 BNC 10 MHz Input: Optional External 10 MHz Reference Input 50 Ohms
J7 BNC 1 PPS Input: Optional External 1 PPS Reference Input 50 Ohms
J9 N RF Output: On Channel RF Output 50 Ohms
J10 IEC
AC Input: AC input connection to 85-264VAC Source and
On/Off circuit breaker
N/A
J11
9 Pos
Male D
Power Monitoring: Interface to System and external amplifier
trays, if present. Also provides an interlock for the Reject
Load (if used).
N/A
J12
15 Pos
Female D
Remote: Remote control and status indications. Refer to
Table 7 on pages 21 & 22 for information on the connections.
N/A
J13 RJ-45
Serial: Provides communication to System and to external
amplifier trays, if present.
N/A
J14 RJ-45
Ethernet: Optional Ethernet connection. May not be present
in your tray.
N/A
J15
Front
Panel
BNC
RF Sample: Output Sample from Output Detector Board.
In a CHV200B the sample level at J15 is approximately 60dB
down from the output power level of the tray.
50 Ohms
J16
Front
Panel
9 Pos
Female D
Serial: Used to load equalizer taps into the modulator. N/A
J1
J11
J12
J10
J6
J9
J
7
J
4
J13
J
5