User's Manual
8 3 6 A 2 k W UHF Tr a nslat or , I nt erna lly Diple x ed Re m ote Cont r ol I nte r face Connect ions
Function Re m ote Ja ck / Pin N o. I n t er face Type
- Page 3 of 4 -
UHF Ex cit e r
Translat or Enable I nt erlock J9- 21 J9-21 & 22 m ust be j um pered
Translat or Enable I nt erlock Rtn. J9-22 t oget her for Norm al Operat ion.
( 1176- 1038) Jum per Jack is used.
UHF Ex cit e r - Continued
Re m ote Cont r ol Com m ands:
Translat or St andby ( Disable) J9-9 Cont act Closure
Translat or St andby/ Operate Rtn. J9- 10
Translat or Operate (Enable) J9-11 Contact Closure
Translat or Manual J9- 15 Contact Closure
Translat or Auto/ Manual Rtn. J9-16
Translat or Auto J9- 17 Contact Closure
Power Level Raise ( Opt ional) J9- 27 Cont act Closure
Pwr Lvl Raise/ Lower Rtn (Opt ional) J9-28
Power Level Lower ( Optional) J9- 29 Contact Closure
Modulat or Select ( Opt ional) J9- 31 Cont act Closure
Modulat or Select Rtn (Opt ional) J9- 32
Re m ote St a t us I ndica t ion s:
Translat or Operate (Enable) I nd. J9- 12 50m A Max. Current Sink
Operat e/ St andby I nd. Return J9- 13
Translat or St andby ( Disable) I nd. J9- 14 50m A Max. Current Sink
Translat or Auto I ndicat or J9- 18 50m A Max. Current Sink
Auto/ Manual I ndicat or Ret urn J9- 19
Translat or Manual I ndicat or J9-20 50m A Max. Current Sink
VSWR Cut back I ndicat or J9- 23 50m A Max. Current Sink
VSWR Cut back I ndicat or Ret urn J9-24
Video Loss ( Fault ) I ndicat or J9- 25 50m A Max. Current Sink
Video Loss ( Fault ) I nd. Rtn. J9-26
Receiver Fault I ndicat or J9-30 50m A Max. Current Sink
Re m ote M e t e r ing:
Visual Out put Power J9- 1 1V full scale at 1k
Visual Out put Power Rtn J9- 2 Source Resistance
Aural Out put Power J9- 3 1V full scale at 1k
Aural Out put Power Rtn J9- 4 Source Resistance