User's Manual
8 3 6 A 2 k W UHF Tr a nslat or , I nt erna lly Diple x ed Re m ote Cont r ol I nte r face Connect ions
Function Re m ote Ja ck / Pin N o. I n t er face Type
- Page 1 of 4 -
The Rem ot e Connect ions, as list ed below, are m ade if the Opt ional ( A17) A/ V I nput & Rem ot e
I nterface Assem bly ( 1276- 1008) is not present in your Syst em . Refer t o the I nt erconnect
Drawing ( 1276-8000) for t he proper Pin Rem ot e Connections.
UHF Ex cit e r
Translat or Enable I nt erlock J11-24 J11- 24 & 23 m ust be jum pered
Translat or Enable I nt erlock Rtn. J11- 23 toget her for Norm al Operat ion.
( 1176- 1038) Jum per Jack is used.
Re m ote Cont r ol Com m ands:
Translat or St andby ( Disable) J11- 22 Contact Closure
Translat or St andby/ Operate Rtn. J11- 21
Translat or Operate (Enable) J11- 20 Contact Closure
Translat or Manual J11-9 Cont act Closure
Translat or Auto/ Manual Rtn. J11- 36
Translat or Auto J11-8 Cont act Closure
Power Level Raise ( Opt ional) J10-11 Cont act Closure
Pwr Lvl Raise/ Lower Rtn (Opt ional) J10- 13
Power Level Lower ( Optional) J10-12 Contact Closure
Modulat or Select ( Opt ional) J11- 10 Contact Closure
Modulat or Select Rtn (Opt ional) J11-28
Re m ote St a t us I ndica t ion s:
Translat or Operate (Enable) I nd. J10-3 50m A Max. Current Sink
Operat e/ St andby I nd. Return J10-16
Translat or St andby ( Disable) I nd. J10- 4 50m A Max. Current Sink
Translat or Auto I ndicat or J11-7 50m A Max. Current Sink
Auto/ Manual I ndicat or Ret urn J11-32
Translat or Manual I ndicat or J11- 6 50m A Max. Current Sink
VSWR Cut back I ndicat or J11-37 50m A Max. Current Sink
VSWR Cut back I ndicat or Ret urn J11- 35
Video Loss ( Fault ) I ndicat or J11-25 50m A Max. Current Sink
Video Loss ( Fault ) I nd. Rtn. J11- 31
Receiver Fault I ndicat or J11- 12 50m A Max. Current Sink
Visual Out put Power J11-26 1V full scale at 1kW
Visual Out put Power Rtn J11-29 source resist ance
Aural Out put Power J11-27 1V full scale at 1kW
Aural Out put Power Rtn J11-30 source resist ance