User Manual
835A 4 kW, 5 kW or 6 kW UHF Transmitter Remote Control Interface Connections
- Page 3 of 3
(A2 and A3) Amplifier Array Assembly Remote Metering - Continued
for 4 kW, 5 kW & 6 kW - continued
(A1) UHF Amp Tray Fwrd Pwr J5-4 1V Full Scale At 1kΩ
(A1) Forward Power Rtn J5-3 Source Resistance
(A2) UHF Amp Tray Refl Pwr J5-6 1V Full Scale At 1kΩ
(A2) Reflected Power Rtn J5-5 Source Resistance
(A2) UHF Amp Tray Fwrd Pwr J5-8 1V Full Scale At 1kΩ
(A2) Forward Power Rtn J5-7 Source Resistance
(A3) UHF Amp Tray Refl Pwr J5-9 1V Full Scale At 1kΩ
(A3) Reflected Power Rtn J5-10 Source Resistance
(A3) UHF Amp Tray Fwrd Pwr J5-11 1V Full Scale At 1kΩ
(A3) Forward Power Rtn J5-12 Source Resistance
(A4) UHF Amp Tray Fwrd Pwr J5-13 1V Full Scale At 1kΩ
(A4) Forward Power Rtn J5-14 Source Resistance
(A4) UHF Amp Tray Refl Pwr J5-15 1V Full Scale At 1kΩ
(A4) Reflected Power Rtn J5-16 Source Resistance
For 5 kW & 6 kW
(A5) UHF Amp Tray Fwrd Pwr J5-17 1V Full Scale At 1kΩ
(A5) Forward Power Rtn J5-18 Source Resistance
(A5) UHF Amp Tray Refl Pwr J5-20 1V Full Scale At 1kΩ
(A5) Reflected Power Rtn J5-21 Source Resistance
For 6 kW
(A6) UHF Amp Tray Fwrd Pwr J5-22 1V Full Scale At 1kΩ
(A6) Forward Power Rtn J5-23 Source Resistance
(A6) UHF Amp Tray Refl Pwr J5-24 1V Full Scale At 1kΩ
(A6) Reflected Power Rtn J5-25 Source Resistance
The above connections are made to Jack (J5), the 37 Position "D" Connector located on (A11) the Remote Interface Panel
mounted at the Top, Rear of each of the Amplifier Array Cabinets.