6X Series Liquid-Cooled Transmitter Chapter 3, Installation, Set Up and
Problem Identification Procedures
Instruction Manual, Rev. 0 3-5
3.3: Main AC Connections
The Electrician should install the Main AC and the control & monitoring conduit for
the transmitter site to meet all NEC regulations and also according to the electrical
system transmitter site drawing. Use conduit, in the size needed for running the
wires, as called out on the Electrical drawing for your site and as required by NEC
regulations.
NOTE: Site grounding is required as recommended by Axcera on the typical
electrical system drawing.
The AC feeds for a typical exciter/amplifier cabinet consist of two 50 Amp 480 VAC 3
wire three phase feeds that are connected to terminal blocks mounted in the cabinet.
Connect the 480 VAC 3 phase inputs to the exciter/amplifier cabinet. The pump
cabinet assembly requires a 20 Amp 480 VAC 3 phase feed. Connect the 480 VAC 3-
phase inputs to the terminal block mounted in the pump cabinet assembly.
3.4: Main AC Power Up and Verification
The Electrician must power up the 480 VAC 3 phase Distribution Panel circuit
breakers, the primary site power and also verify the operation of the surge
suppressor and voltage regulator, if present.
6X Typical Electrical System