Specifications

Date:26-JULY-2020
Page: 32
A
ssociation Group
2/3
Parameter No. 0x43 (67)
Name AG3 - Remote Water Leak Cancellation
Info Remote Water Leak Cancellation Basic SET
Properties
Size
1 Byte
Min Value
0x00 (0)
Format
Enumerated
Max Value
0x02 (2)
Read only
False
Default Value
0x00 (0)
Altering capabilities
False
Advanced
False
Description Configure Association Group 3 Basic Set value when Remote Water Leak cancelled
Value Function
0x00 (0) Disable Basic Set (Send nothing)
0x01 (1) Basic ON (0xFF)
0
x02 (2)
Ba
sic OFF (0x00)
Parameter No. 0x44 (68)
Name AG4 - Overheat Trigger Value
Info Overheat Trigger Value Basic SET
Properties
Size
1 Byte
Min Value
0x00 (0)
Format
Enumerated
Max Valu e
0x02 (2)
Read only
False
Default Value
0x00 (0)
Altering capabilities
False
Advanced
False
Description Configure Association Group 4 Basic Set value when Overheat Triggered
Value Function
0x00 (0) Disable Basic Set (Send nothing)
0x01 (1) Basic ON (0xFF)
0x02
(2)
B
asic OFF (0x00)
Parameter No. 0x45 (69)
Name AG4 - Overheat Recover Value
Info Overheat Recover Value Basic SET
Properties
Size
1 Byte
Min Value
0x00 (0)
Format
Enumerated
Max Value
0x02 (2)
Read only
False
Default Value
0x00 (0)
Altering capabilities
False
Advanced
False
Description Configure Association Group 4 Basic Set value when Overheat Recovered
Value Function
0x00 (0) Disable Basic Set (Send nothing)
0x01 (1) Basic ON (0xFF)
0
x02 (2)
B
asic OFF (0x00)