Specifications

Date:26-JULY-2020
Page: 31
A
ssociation Group
1/3
Parameter No. 0x40 (64)
Name AG2 - Built-in Water Leak Trigger
Info Built-in Water Leak Trigger Basic SET
Properties
Size
1 Byte
Min Value
0x00 (0)
Format
Enumerated
Max Value
0x02 (2)
Read only
False
Default Value
0x01 (1)
Altering capabilities
False
Advanced
False
Description Configure Association Group 2 Basic Set value when Built-in Water Leak triggered
Value Function
0x00 (0) Disable Basic Set (Send nothing)
0x01 (1) Basic Set ON (0xFF)
0
x02 (2)
B
asic Set OFF (0x00)
Parameter No. 0x41 (65)
Name AG2 - Built-in Water Leak Cancellation
Info Built-in Water Leak Cancellation Basic SET
Properties
Size
1 Byte
Min Value
0x00 (0)
Format
Enumerated
Max Value
0x02 (2)
Read only
False
Default Value
0x00 (0)
Altering capabilities
False
Advanced
False
Description Configure Association Group 2 Basic Set value when Built-in Water Leak Cancelled
Value Function
0x00 (0) Disable Basic Set (Send nothing)
0x01 (1) Basic Set ON (0xFF)
0
x02 (2)
B
asic Set OFF (0x00)
Parameter No. 0x42 (66)
Name AG3 - Remote Water Leak Trigger
Info Remote Water Leak Trigger Basic SET
Properties
Size
1 Byte
Min Value
0x00 (0)
Format
Enumerated
Max Value
0x02 (2)
Read only
False
Default Value
0x01 (1)
Altering capabilities
False
Advanced
False
Description Configure Association Group 3 Basic Set value when Remote Water Leak triggered
Value Function
0x00 (0) Disable Basic Set (Send nothing)
0x01 (1) Basic ON (0xFF)
0
x02 (2)
Basic OFF
(0x00)