Specifications

Date:26-JULY-2020
Page: 27
16.10 Configuration CC
Note: No Bulk Support equals to True. It will return an Application Rejected Request Command when receiving
Configuration Bulk Set or Get (if received without Supervision encapsulation). It will reset all its configuration
parameters if either manually reset to factory default or receives a Configuration Default Reset Command. It will NOT
modify or reset any configuration parameter when being included or excluded of a Z-Wave network
Sensor Function
Parameter No. 0x10 (16)
Name Sensors Function Set
Info Sensors Function Enable / Disable
Properties Size 1 Byte Min Value 0x00 (0)
Format Bit Field Max Value 0x0F (15)
Read only False Default Value 0x0F (15)
Altering capabilities False Advanced False
Description Water Leak Probes & Temperature Function Set Disable / Enable *(Default all enabled)
Value Function
Bit 0 Built-in Water Detection Probe *(Default Enabled)
Bit 1 Remote Water Detection Probe *(Default Enabled)
Bit 2 Overheat Detection *(Default Enabled)
Bit 3 Freeze Detection *(Default Enabled)
Parameter No. 0x11 (17)
Name Water Leak Cancellation Basic SET
Info Water Leak Probes Cancellation for AG2 AG3
Properties Size 1 Byte Min Value 0x00 (0)
Format Enumerated Max Value 0x01 (1)
Read only False Default Value 0x01 (1)
Altering capabilities False Advanced False
Description Configure Water Leak Cancellation Basic SET for Built-in (AG2) / Remote Sensor (AG3) Probes, related parameters 0x41 & 0x43
Value Function
0x00 (0) Send Basic SET when Water Alarm CancelledEither” Built-in orRemote Water Detection Probe
0x01 (1) Send Basic SET when Water Alarm Cancelled Built-in And Remote Water Detection Probe