Specifications
Date:26-JULY-2020
Page: 24
16.4 Notification CC
Notification
Type
Notification Events / State Description
Heat Alarm 0x04 State idle 0x00 Notification value for the state variable going to idle (V5)
Overheat detected
0x02 No Location Support Event
Underheat detected 0x06 No Location Support Event
Water Alarm 0x05 State idle 0x00 Notification value for the state variable going to idle (V5)
Water leak detected 0x02 No Location Support Event
Power
Management
0x08 State idle 0x00 Notification value for the state variable going to idle (V5)
Battery fluid is low 0x11
16.5 Indicator CC
Parameter Value
Indicator ID 0x50 = (Node Identify)
Property ID 0x03 = (On/Off Periods)
0x04 = (On/Off Cycles)
0x05 = (On time within an On/Off period)
16.6 Basic CC Mapping of Water WWD
Basic Command Class does not map to any Command Class
16.7 Wake Up CC
Wake Up Interval Capabilities Report
Parameter Value Time
Min Wake Up Interval (Seconds) 0x000014 20 Seconds
Max Wake Up Interval (Seconds) 0x015180 86400 Seconds (24 Hours)
Default Wake Up Interval (Seconds) 0x001C20 7200 Seconds (2 Hours)
Wake Up Interval Step (Seconds) 0x000014 20 Seconds