Operation Manual
1. Product Detail
- Main Chip: STM32L083
- RF Chip: SX1261
- GSensor: LIS3DH with built-in Temperature Sensor
- Leak Sensor: Dual Water Leak Sensor Probe
- Buzzer
2. RF Regulation (Do we need to configure sub-band and frequency?)
2.1. Modulation:
- (G)FSK
2.2. US frequency bank(Sub-bank Set? Production PLC Setting)
- 64 Channels uplink from 902.3MHz – 914.9MHz @ 125K
- 8 Channels uplink from 903.0MHz – 914.2 MHz @ 500K
- 8 Channels downlink from 923.3MHz – 927.5MHz @ 500K
2.3. EU Frequency Bank (Sub-bank Set? Production PLC Setting)
- Channel Uplink?
- Channel Downlink?
3. Power Supply
3.1. Battery ER14250 3.6V 1200mA
4. Features
5. Key & LED Operation “UI” (Others UI, please refer Z-Wave UI Definition. Eg.
Timeout, Fail, Power OK..)
5.1. BVS Working Mode
5.1.1. Shipping mode
5.1.1.1. By default, before ship out, the Shipping mode is enabled to let Lipstick goes into
lower power consumption during transportation.
5.1.1.2. To disable Shipping mode before installation.
- Trigger and hold Water Leak Sensor for 10 Seconds
- LED keeps blinking.
- Buzzer Sound ON 1 second.
5.1.2. Standalone mode
- Yellow LED blinking (Heartbeat, refer to Z-Wave UI)
5.1.3. Network mode
- Green LED blinking (Added into Simple Ubilink network with fair RF signal)
- Red LED blinking (Added into Simple Ubilink network with poor RF signal)
5.2. Inclusion/ Exclusion (Active low RF power mode during Inclusion/Exclusion, only accept
RF range within 1-1.5 meters)
5.2.1. ManualInclusion Mode
5.2.1.1. Procedure& UI
- Trigger and wakeup Lipstick
- Place and hold Lipstick in Vertical position.
- Waiting Ready UI
- Keep Lipstick in Vertical and Shake it in Horizontal “Left→ Right”
- (Green LED and Buzzer) Turn ON 1 second.
- UI will change to Network Mode status
5.2.2. ManualExclusion Mode
5.2.2.1. Procedure& UI
- Trigger and wakeup Lipstick
- Place and hold Lipstick in Vertical position.
- Waiting Ready UI
- Keep Lipstick in Vertical and Shake it in Horizontal level “Left → Right”
- (Green LED and Buzzer) Turn ON 1 second.
- UI will change to Standalone Mode status.
5.3. Heartbeat Frame
5.3.1. Heartbeat function
- Sends Battery Report to BVS every 24 hours,
- Heartbeat tells BVS it’s still alive.
5.4. Water Leak Alarm&Cancellation
5.4.1. Water Leak Alarm. (Sends out to BVS)
- Trigger Local Water Leak Sensor Probe
- Or Trigger Remote Water Leak Sensor Probe.
- Sends out Alarm Frame to BVS
- UI – Battery above 50% (Red LED & Buzzer sound 1Hz)