Managed PoE+ Gigabit Switch with SFP Model: US-16-150W
Introduction Thank you for purchasing the Ubiquiti Networks® UniFi® Switch. This Quick Start Guide is designed to guide you through the installation and also includes the warranty terms. Package Contents UniFi Switch US-16-150W Power Cord Rack-Mount Brackets (Qty. 2) Bracket Screws (Qty. 8) Managed PoE+ Gigabit Switch with SFP Model: US-16-150W Mounting Screws (Qty. 4) Cage Nuts (Qty. 4) Rubber Feet (Qty.
System Requirements • Linux, Mac OS X, or Microsoft Windows 7/8/10 • Java Runtime Environment 1.6 (1.8 or newer recommended) • Web Browser: Google Chrome (Other browsers may have limited functionality.) • UniFi Controller software v5.4.x or above, available at: downloads.ubnt.
Network Topology Requirements • A DHCP-enabled network for the UniFi Switch to obtain an IP address (connected devices will also obtain IP addresses after deployment) • A UniFi Cloud Key or management station running the UniFi Controller software v5.4.
Hardware Overview Front Panel RJ45 1-16 SFP 1-2 Reset Button Port Description RJ45 1-16 RJ45 ports support Power over Ethernet (PoE) and 10/100/1000 Ethernet connections. SFP 1-2 Hot-swappable SFP ports support 1 Gbps connections. This button serves two functions for the UniFi Switch: Reset Button • Restart Press and release the Reset button quickly. • Restore to Factory Default Settings Press and hold the Reset button for more than five seconds.
Front Panel System LED System State Status White Factory defaults, waiting for integration. Flashing White Initializing. Alternating White/Blue Device is busy; do not use or unplug it. This usually indicates that a process such as a firmware upgrade is taking place. Blue Successfully integrated into a network and working properly. This is used to locate a device. Flashing Blue When you click Locate in the UniFi Controller software, the System LED will flash blue.
Front Panel Port LEDs RJ45 PoE LED RJ45 Speed/Link/Act SFP Speed/Link/Act State Status Off No PoE Amber IEEE 802.3af/802.
Back Panel Console Port Console Ventilation Fans Power Description RJ45 serial console port for Command Line Interface (CLI) management. Use an RJ45‑to-DB9, serial console cable, also known as a rollover cable, to connect the Console port to your computer.
Hardware Installation The UniFi Switch can be placed on a horizontal surface, mounted in a rack, or mounted on a wall. WARNING: FAILURE TO PROVIDE PROPER VENTILATION MAY CAUSE FIRE HAZARD. KEEP AT LEAST 20 MM OF CLEARANCE NEXT TO THE VENTILATION HOLES FOR ADEQUATE AIRFLOW. Mounting in a Rack (Optional) 1. Attach the Rack-Mount Brackets to the UniFi Switch using the eight Bracket Screws. 2. Attach the UniFi Switch to the rack using the four Mounting Screws.
Connecting Power 1. Connect the Power Cord to the Power port of the UniFi Switch. 2. Connect the other end of the Power Cord to a power outlet.
Connecting Ethernet 1. Connect a UniFi Cloud Key, management computer, or LAN running the UniFi Controller to the UniFi Switch. 2. Connect Ethernet cables from the gateway or router (DHCP server) and other devices to the UniFi Switch.
Using SFP Ports To use an SFP port: 1. Remove the protective plug covering the SFP port. 2. Plug a compatible fiber module into the SFP port. D D M K 0 m 2 n CS 0 1 /M 3 1 S xR s /m pb n M 0 0 5 0 5 0 1 1 xT M 3. Connect the fiber optic cable to the fiber module. Then connect the other end of the cable to another fiber device. For information about compatible fiber SFP modules, visit: community.ubnt.
Software Installation Download and install the latest version of the UniFi Controller software at downloads.ubnt.com/unifi and follow the on‑screen instructions. Note: If you already have UniFi Controller v5.4.x or newer installed, skip to the section, Adopting the UniFi Switch. After you have installed the software and run the UniFi Installation Wizard, a login screen will appear for the UniFi Controller management interface. Enter the admin name and password that you created and click Log In.
Adopting the UniFi Switch 1. From the UniFi Controller dashboard, click Devices in the left menu bar. 2. On the Devices screen, locate the UniFi Switch in the list of devices under the Model column. To adopt the UniFi Switch, click Adopt. 3. The System LED on the UniFi Switch will turn blue to confirm that it has been successfully adopted.
Configuring PoE Settings The RJ45 ports are auto-sensing by default, so 802.3af/at devices can be plugged in and automatically receive Power over Ethernet. To disable or enable PoE, follow these instructions: 1. On the Devices screen, locate the UniFi Switch in the list of devices under the Model column. Click its Name/MAC Address to access its settings. 2. Click the Ports tab.
3. Click Actions for the port you want to configure. 4. Select the appropriate PoE setting: Off or PoE+. Then click Apply. For more information, refer to the User Guide on the website: documentation.ubnt.
Specifications UniFi Switch US-16-150W Dimensions Weight With Mount Brackets Total Non-Blocking Line Rate Max. Power Consumption Power Method Power Supply Rack-Mount LEDs Per Port RJ45 Data Ports SFP Data Ports Interfaces Networking Interfaces Management Interface PoE Output (RJ45 Ports) PoE Voltage Range 802.3at Mode Max. PoE+ Wattage per Port Operating Temperature 443 x 43 x 221 mm (17.44 x 1.69 x 8.70") 2.80 kg (6.17 lb) 2.89 kg (6.
Safety Notices 1. Read, follow, and keep these instructions. 2. Heed all warnings. 3. Only use attachments/accessories specified by the manufacturer. WARNING: Failure to provide proper ventilation may cause fire hazard. Keep at least 20 mm of clearance next to the ventilation holes for adequate airflow. WARNING: To reduce the risk of fire or electric shock, do not expose this product to rain or moisture. WARNING: Do not use this product in location that can be submerged by water.
Limited Warranty UBIQUITI NETWORKS, Inc (“UBIQUITI NETWORKS”) warrants that the product(s) furnished hereunder (the “Product(s)”) shall be free from defects in material and workmanship for a period of one (1) year from the date of shipment by UBIQUITI NETWORKS under normal use and operation.
Returns No Products will be accepted for replacement or repair without obtaining a Return Materials Authorization (RMA) number from UBIQUITI NETWORKS during the warranty period, and the Products being received at UBIQUITI NETWORKS’ facility freight prepaid in accordance with the RMA process of UBIQUITI NETWORKS. Products returned without an RMA number will not be processed and will be returned freight collect or subject to disposal.
Limitation of Liability EXCEPT TO THE EXTENT PROHIBITED BY LOCAL LAW, IN NO EVENT WILL UBIQUITI OR ITS SUBSIDIARIES, AFFILIATES OR SUPPLIERS BE LIABLE FOR DIRECT, SPECIAL, INCIDENTAL, CONSEQUENTIAL OR OTHER DAMAGES (INCLUDING LOST PROFIT, LOST DATA, OR DOWNTIME COSTS), ARISING OUT OF THE USE, INABILITY TO USE, OR THE RESULTS OF USE OF THE PRODUCT, WHETHER BASED IN WARRANTY, CONTRACT, TORT OR OTHER LEGAL THEORY, AND WHETHER OR NOT ADVISED OF THE POSSIBILITY OF SUCH DAMAGES.
Compliance FCC Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: 1. This device may not cause harmful interference, and 2. This device must accept any interference received, including interference that may cause undesired operation.
Australia and New Zealand Warning: This is a Class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures. CE Marking CE marking on this product represents the product is in compliance with all directives that are applicable to it.
RoHS/WEEE Compliance Statement English European Directive 2012/19/EU requires that the equipment bearing this symbol on the product and/or its packaging must not be disposed of with unsorted municipal waste. The symbol indicates that this product should be disposed of separately from regular household waste streams. It is your responsibility to dispose of this and other electric and electronic equipment via designated collection facilities appointed by the government or local authorities.
Español La Directiva 2012/19/UE exige que los equipos que lleven este símbolo en el propio aparato y/o en su embalaje no deben eliminarse junto con otros residuos urbanos no seleccionados. El símbolo indica que el producto en cuestión debe separarse de los residuos domésticos convencionales con vistas a su eliminación.
Declaration of Conformity Česky [Czech] UBIQUITI NETWORKS tímto prohlašuje, že toto UBIQUITI NETWORKS zařízení, je ve shodě se základními požadavky a dalšími příslušnými ustanoveními směrnic 2014/30/EU, 2014/35/EU. Dansk [Danish] Hermed, UBIQUITI NETWORKS, erklærer at denne UBIQUITI NETWORKS enhed, er i overensstemmelse med de væsentlige krav og øvrige relevante krav i direktiver 2014/30/EU, 2014/35/EU.
UBIQUITI NETWORKS deklaruoja, kad šis UBIQUITI NETWORKS Lietuviškai [Lithuanian] įrenginys atitinka esminius reikalavimus ir kitas 2014/30/ES, 2014/35/ES Direktyvų nuostatas. Malti [Maltese] Hawnhekk, UBIQUITI NETWORKS, tiddikjara li dan il-mezz UBIQUITI NETWORKS huwa konformi mar-rekwiżiti essenzjali u dispożizzjonijiet rilevanti oħrajn ta ‘Direttivi 2014/30/UE, 2014/35/UE.
Online Resources Support help.ubnt.com Community community.ubnt.com Downloads downloads.ubnt.com www.ubnt.com ©2015-2017 Ubiquiti Networks, Inc. All rights reserved. Ubiquiti, Ubiquiti Networks, the Ubiquiti U logo, the Ubiquiti beam logo, TOUGHCable, and UniFi are trademarks or registered trademarks of Ubiquiti Networks, Inc. in the United States and in other countries. All other trademarks are the property of their respective owners.