User's Manual

45
Appendix B: AF-5X and airFiber MultiplexerairFiber X User Guide
Ubiquiti Networks, Inc.
Appendix B: AF-5X and
airFiber Multiplexer
Note: This appendix applies to the airFiber AF-5X
radio when used with the airFiber NxN Multiplexer.
The following provides important information for using
the AF-5X radio with the airFiber NxN Multiplexer (models
AF-MPx4 or AF-MPx8). For a successful deployment,
ensure that all additional steps are taken and that all
information is taken into consideration.
During initial configuration of each AF-5X radio, input
the additional cable loss associated with the multiplexer,
and enable the NxN Radio setting. For details, refer to
Step 6 of airFiber Configuration” on page4.
When performing antenna alignment, perform the
procedure in “Establishing a Link” on page9 on
one radio only. This will help ensure maximum success
in registrations.
After the first radio has been aligned with the other side
of the link, ensure that the TX power balance is present.
To maintain 8x performance, maximum TX power
should not exceed 19-20 dBm.
If 8x performance cannot be achieved at these TX power
levels, it may be possible to improve performance by
increasing channel spacing.
airFiber X Compatibility
The airFiber NxN is designed for use with airFiber 5X
radios, (model AF-5X) and 5 GHz airFiber X or RocketDish
antennas.
Note: The airFiber X Antenna OMT Conversion Kit
(AF-5G-OMT-S45) is highly recommended when
using a RocketDish for proper fitting and improved
frequency isolation.
Installation Requirements
(2) airFiber 5X radios for AF-MPx4
(4) airFiber 5X radios for AF-MPx8
airFiber X or RocketDish antenna
Clear view of the sky for proper GPS operation
Ground wires – min. 10 AWG (5 mm
2
) and max. length:
1m. Asa safety precaution, ground the airFiber radios to
grounded masts, poles, towers, or grounding bars.
WARNING: Failure to properly ground your
airFiber radio will void your warranty.
Note: For guidelines about grounding and
lightning protection, follow your local electrical
regulatorycodes.
Outdoor, shielded Category 6 (or above) cabling and
shielded RJ-45 connectors are required for all wired
Ethernetconnections.
Hardware Overview
airFiber NxN Multiplexer
Chain 0
Chain 1
RF Cables
(AF-MPx8 Shown)
Chain 0 Connect the antenna RF +45° to this connector.
Chain 1 Connect the antenna RF -45° to this connector.
RF Cables Connect each RF Cable pair to the
corresponding RFconnection chain on each airFiber 5X
radio. For example, connect cable A0 to Chain 0, and
cable A1 to Chain 1.