Programming instructions
Intermec Fingerprint v7.61 – Programmer’s Reference Manual Ed. 7  189
Chapter 2 Program Instructions
PORTOUT ON/OFF
Field of Application
 Statement for setting one of four relay port or one of eight optical ports 
on an Industrial Interface Board to either on or off.
Syntax PORTOUT (<nexp>) ON|OFF
<nexp> is the number of the port to be set:
 OUT ports (relay):    201-204
 OUT ports (optical):    221-228
Remarks
 This  statement  works  with  the  Industrial  Interface  Board  and  is  able  to 
control 8 IN ports with optocouplers, 8 OUT ports with optocouplers, and 
4 OUT ports with relays. For information on how to read the status of the 
various ports, please refer to the PORTIN function.
 This feature is intended to allow the execution of the Intermec Fingerprint 
program to control various external units like gates, lamps, or conveyor 
belts. 
 Please refer to the  documentation of the Industrial  Interface Board for 
more information.
Example
 The  relay  of OUT port  201  on  an Industrial Interface Board  is  Opened 
and then Closed like this:
  . . . . .
  . . . . .
  1000   PORTOUT (201) ON
  . . . . .
  . . . . .
  2000   PORTOUT (201) OFF
  . . . . .
  . . . . .