Programming instructions

Intermec Fingerprint v7.61 Programmers Reference Manual Ed. 7 189
Chapter 2 Program Instructions
PORTOUT ON/OFF
Field of Application
Statement for setting one of four relay port or one of eight optical ports
on an Industrial Interface Board to either on or off.
Syntax PORTOUT (<nexp>) ON|OFF
<nexp> is the number of the port to be set:
OUT ports (relay): 201-204
OUT ports (optical): 221-228
Remarks
This statement works with the Industrial Interface Board and is able to
control 8 IN ports with optocouplers, 8 OUT ports with optocouplers, and
4 OUT ports with relays. For information on how to read the status of the
various ports, please refer to the PORTIN function.
This feature is intended to allow the execution of the Intermec Fingerprint
program to control various external units like gates, lamps, or conveyor
belts.
Please refer to the documentation of the Industrial Interface Board for
more information.
Example
The relay of OUT port 201 on an Industrial Interface Board is Opened
and then Closed like this:
. . . . .
. . . . .
1000 PORTOUT (201) ON
. . . . .
. . . . .
2000 PORTOUT (201) OFF
. . . . .
. . . . .