Specifications
Chapter 5— Advanced Printer Programming
54 IPL Programmer’s Reference Manual
The second 2.54 cm (1 in) section of the label is imaged into the second
image band. Printing still has not started.
IPL.014
The third 2.54 cm (1 in) section of the label is imaged into the third image
band. Printing begins from the first image band, as indicated by the arrow.
At this point, all three available image bands have been filled. The first
band will be reused after it has been completely printed.
IPL.015
When the first image band is emptied (printed), the fourth band is imaged
into it. Printing continues from the second image band. As before, this
band must be emptied before the final band can be imaged into it.
IPL.016
The final section of the label is imaged into the second image band.
Printing continues from the third band. At this point, the label has been
completely imaged, but not printed.