Specifications

Chapter 4— Troubleshooting
IPL Programmer’s Reference Manual 47
Error Codes and Possible Solutions (continued)
Error
Code
Description of Problem
Solution
32 Non-immediate command or data received
after buffer full.
Allow the printer to empty the buffer contents before
sending commands or data.
33 Invalid field delimiters. Check for all pairs of field delimiters and make sure both
are numeric, or both are alphanumeric.
34 Invalid escape command. Correct the escape command syntax.
35 Invalid data shift command. Correct the shift command syntax.
36 Invalid or undefined format number. Verify that the format numbers are between 0 and 19.
37 Insufficient room in RAM to print format. Reduce the number of data fields in the format or add
more DRAM.
38 Invalid or undefined field number. Verify the field number in the label format.
41 Syntax error for program commands. Check the program command for proper syntax.
Empty the buffer contents. If the format still does not fit,
delete some fields or other data from the format. You
may have to remove or reduce the UDCs, formats, or
fonts if necessary.
42 Insufficient room in RAM to store format.
Note: Entering <ESC>m tells the host how much
memory is installed and how much is available.
43 Too many fields in label format. You can use up to 200 fields in a format and each field
can use up to 250 characters. Reduce field size or delete
some fields.
46 Undefined statement. Check the statement syntax.
52 Invalid UDC/UDF bitmap cell height/width
or intercharacter space.
Verify that the UDC/UDF bitmap cell height/width or
intercharacter space is within the specified values for n.
For more information, see the Bitmap Cell Height/Width
for Graphic or UDF, Define or the Intercharacter Space
for UDF, Define command in Chapter 7.
53 Insufficient room in RAM to store UDC or
UDF.
Remove or reduce formats, fonts, or UDCs.
54 Invalid UDC command syntax. Correct the UDC command syntax.