Specifications
Chapter 7— IPL Command Reference
IPL Programmer’s Reference Manual 175
Field Direction, Define
Purpose: Defines the field rotation.
Syntax: fn
Printers:
Printer Default Values for n
All n = 0
0 = Horizontal
1 = Rotated 90° counterclockwise from horizontal
2 = Rotated 180° counterclockwise from horizontal
3 = Rotated 270° counterclockwise from horizontal
Field Origin, Define
Purpose: Defines the origin for a field. The field origin is the upper left corner of
the field. Horizontal n and vertical m locations represent the number of
dots from the label’s origin. The origin (0,0) is the upper left square on the
label.
Syntax: on,m
Printers:
Printer Default Values for n and m
All
n = 0
,m = 0
n = 0 to 19999
,m = 0 to 19999