Specifications

Chapter 7— IPL Command Reference
156 IPL Programmer’s Reference Manual
Bar Code, Select Type (continued)
This example illustrates the command for MaxiCode Mode 2:
<STX><ESC>C<ETX>
<STX><ESC>P<ETX>
<STX>E1;F1<ETX>
<STX>H0;o10,10<ETX>
<STX>B1;o100,300;f1;c14,2;h6;w6;d0,100<ETX>
<STX>R<ETX>
<STX><ESC>E1<CAN><ETX>
<STX>MaxiCode Sample Mode 2<CR><ETX>
<STX>[)><SUB><RS>01<SUB><GS>01982039280<SUB><GS>840<SUB>
<GS>001<SUB><GS>1Z94924221455215<SUB><RS>Intermec 6001
36th Ave West Everett, WA 98203<SUB><EOT><ETX>
<STX><ETB><ETX>
This example illustrates the command for MaxiCode Mode 3:
<STX><ESC>P<ETX>
<STX>E1;F1<ETX>
<STX>H0;o10,10<ETX>
<STX>B1;o100,300;f1;c14,3;h6;w6;d0,100<ETX>
<STX>R<ETX>
<STX><ESC>E1<CAN><ETX>
<STX>MaxiCode Sample Mode 3<CR><ETX>
<STX>[)><SUB><RS>01<SUB><GS>96T51654<SUB><GS>484<SUB>
<GS>066<SUB><GS>1Z00000256<SUB><RS><SUB><EOT><ETX>
<STX><ETB><ETX>
JIS-ITF
c15[,m]
The default for m is 0.
Values for m
m Description
0 Selects 5 dot narrow bar width magnification.
1 Selects 8 dot narrow bar width magnification.
2 Selects 10 dot narrow bar width magnification.
The next command defines a data source for the current field and how
many characters are in the field.
d[n][,m]
The default for n,m is 0,14.