Specifications

Chapter 7— IPL Command Reference
IPL Programmer’s Reference Manual 155
Bar Code, Select Type (continued)
This table lists the possible values for ,m1. The default value
autodiscriminates between Modes 2, 3, and 4.
Note: If you have developed previous applications using Mode 0, your
printer will still support your application; however, we recommend using
Mode 2 or 3 for new applications.
Values for m1
m1 Description
2 Structured Carrier Message for numeric postal codes up to 9 digits
3 Structured Carrier Message for alphanumeric postal codes up to 6 characters
4 Standard Symbol
5 Full Enhanced Error Correction (EEC)
6 Reader Programming
When you select MaxiCode, you must format your data to conform to the
five fields described in the next table.
Note: The header only applies to Structured Carrier Message (Modes 2 and
3). The Structured Carrier Message header is optional.
MaxiCode Fields
Field Description of Field Number of Characters Default
1 Header (optional) Nine None
2 Postal code Six or nine None
3 Country code Three 840 (U.S.)
4 Service class Three 999
5 Secondary Message 84 None
1 2 3 4 5
IPL.018
p
Notes: The NULL character is not supported. If the NULL character appears in
the user data, you will lose it along with any following data.
All control characters (<RS>, <GS>, <EOT>, etc.) must be preceded by a
<SUB> character, as illustrated in the following examples.