Specifications

Chapter 7— IPL Command Reference
IPL Programmer’s Reference Manual 147
Bar Code, Select Type (continued)
The flag 1 option only applies to EAN 8, EAN 13, and UPC version A.
For EAN 13, enabling the flag 1 option prints the first character of the bar
code interpretive. For EAN 8 and UPC version A, enabling the flag 1
option moves the first and last character of the bar code interpretive
outside of the guard bars.
UPC Versions D1 - D5 are not supported in the 3400 C/D, 3400e, 4420,
4440, EasyCoder F4, PF2i, PF4i and PM4i printers.
HIBC Code 39
c8[,m1][,m2]
The default for m1 is 0.
Values for m1 Conforming to the Supplier Standard
m1 Description
0 Selects HIBC Code 39. Primary format.
1 Selects HIBC Code 39. Alternate primary format.
2[,m2] Selects HIBC Code 39. Secondary format. The linkage character comes
from ,m2, which is the field identifier.
Values for m1 Conforming to the Provider Standard
m1 Description
3 Single format.
4 First data format.
5[,m2] Selects HIBC Code 39. Second data format. The linkage character comes
from ,m2, which is the field identifier.
6 Selects HIBC Code 39. Multiple data format.
Code 16K
c9
In Emulation mode, use a <SUB> 1 to represent the function 1 character.
To represent the function 1 character in Advanced mode, enter
<SUB><SUB> 1. Represent the characters for functions 2, 3, and 4 in the
same way.
To produce a square symbol, specify a height magnification of 1 in
Advanced mode. To specify a square symbol, use a height magnification of
250 in Emulation mode.