Specifications
Chapter 7— IPL Command Reference
IPL Programmer’s Reference Manual 139
Takeup Motor Torque, Increase
Purpose: Increases the takeup motor torque from 0 to 50% above the default value.
For printers with firmware version 2.5, varies the torque from 75% below
to 50% above the default value.
Syntax: <SI>bn
Printers:
Printer Default Values for n
44X0 n = 0
0 to 50
-75 to 50 for firmware version 2.5
Notes: In high humidity environments, you may want to use this command with
the Label Width, Set command.
Top of Form, Set
Purpose: Sets the top of form (left margin or start print point) to n, which is the
distance in 5 mil increments from the label origin to its leading edge.
Syntax: <SI>Fn
Printers:
Printer Default Values for n Notes
All n = 20
-10 to 4000
(in 5 mil increments)
The negative values for n let you
decrease the margin and print closer
to the edge of the label.