Specifications

Chapter 7— IPL Command Reference
IPL Programmer’s Reference Manual 137
Ribbon Save Zones, Set
Purpose: Defines the start and stop points of a ribbon save zone within the label.
This command does not enable interlabel ribbon save.
Syntax: <SI>Zn[,m]
n and ,m are the zone start and zone stop distances, in dot increments,
from the detected front of the label.
The difference between m and n depends on the speed (number of ips) at
which you are printing. Also, m must be bigger than n by at least 100, or
the command will be ignored.
Printers:
Printer Notes
4100
The ribbon save option must be installed or the printer will ignore this
command. Setting a ribbon save zone enables ribbon save. Entering no
ribbon save zones clears all ribbon save zones within this label. If only one
parameter is entered, the command is ignored. The maximum number of
zones possible on one label is 10. This command is buffered up and
becomes effective upon execution.
Self-Strip, Enable or Disable
Purpose: Turns the self-strip (label taken sensor) option on or off.
Syntax: <SI>tn
Printers:
Printer Default Values for n Notes
3240 n = 0
0 = disabled
1 = enabled
3400 n = 0
0 = disabled
1 = enabled
3440 n = 0
0 = disabled
1 = enabled
3600 n = 0
0 = disabled
1 = enabled
4100 N/A N/A
The 4100 printer ignores this command;
however, you can enable self-strip by using
the DIP switches.
4400 n = 0
0 = disabled
1 = enabled
You must install the self-strip option from the
control panel before you can enable or disable
the label taken sensor.
44X0 n = 0
0 = disabled
1 = enabled