Specifications
Chapter 7— IPL Command Reference
110 IPL Programmer’s Reference Manual
Program Number, Transmit
Purpose: Transmits both the program number and the version number.
Syntax: <ESC>Mn
n = 0 returns program # and version #
n = 1 returns program #, version #, and model #
The default for n is 0.
<ESC>M1 is supported by 4420, 4440, and 3400e only.
Here is an example of what you might see: 059877,1.4.
3400e: <ESC>M1 returns program #, version # 3400E2 or E4 (200
dpi/400 dpi)
Notes: This command uploads the program and software version number to the
host as an ASCII alphanumeric character string.
Quantity Count, Set
Purpose: Sets the quantity of label batches to be printed by the next print
command.
Syntax: <RS>n
where n is the number of batches.
Printers:
Printer Default Values for n Notes
All n = 1 1 to 9999 All printers support this command the same way.
Here is an example of how to use this command:
<STX><RS>5<ETB><ETX>
Notes: The printer generates an error code (21) if the quantity is out of range.
Data increments or decrements between batches of labels.
Start and Stop Codes (Code 39), Print
Purpose: Instructs the current Code 39 field to print only the start and stop
characters.
Syntax: <ESC><SP>
where <SP> is the space character.
Notes: The printer clears all previous data from the current field.