operation manual

Dear Customer,
we congratulate you on the purchase of a product from the high-quality Ubbink BioBalance pond lter series.
With these instructions for use, you receive important information which is useful for the assembly, commissioning and maintenance of your BioPressure pressure lter. Please read
these instructions for use prior to installation of the lter, and familiarise yourself with the device. It is essential that you observe the safety guidelnes for correct and safe use. Please
store these instructions for use carefully!
Scope of delivery
1 Pressure lter BioPressure II with integrated UV-C device
1 Universal hose nozzle 40-32-25-19mm, transparent
2 Universal hose nozzle 40-32-25-19mm, black
3 Sealing rings 1 ½“
1 Threaded ring with sealing cap (glass)
1 Instructions for use
Technical data
BioPressure II 3000 6000 10000 18000
Article No. 1355408 1355409 1355410 1355413
Filter contents 10 Liter 10 Liter 15 Liter 25 Liter
Filter medium Special multi-level lter mat Special multi-level lter mat Special multi-level lter mat Special multi-level lter mat
Pressure load max. 0,49 bar max. 0,49 bar max. 0,49 bar max. 0,49 bar
UV-C lamp PL-S 5 W PL-S 9 W PL-S 11 W PL-L 18 W
Mains voltage /frequency 230 VAC / 50 Hz 230 VAC / 50 Hz 230 VAC / 50 Hz 230 VAC / 50 Hz
Cable length 4,5 m 4,5 m 4,5 m 4,5 m
UV-C power after approx. 5,000 hrs. 85% 85% 85% 85%
Article No. for replacement UV-C
quartz glass
1358765 1358766 1358730 1358767
Article No. for UV-C replacement
lamp
1355109 1355110 1355112 1355115
Max. pond content 3.000 Liter 6.000 Liter 10.000 Liter 18.000 Liter
Symbols & setting options
Water inlet from the pump to the lter
Water outlet from the lter into the pond
Water outlet in cleaning operation
“Filter operation” function switch
“Cleaning operation“ function switch
Safety guidelines
WARNING: UV radiation is hazardous to the eyes and skin. The UV-C lamp may not be operated if it has been taken out of the device housing!
CAUTION: This unit contains a UV-C lamp! Inadvertent use of the device or damage to the housing can cause the leakage of hazardous UV-C radiation. Even
low doses of UV-C radiation can cause damage to the eyes and skin.
The power supply must accord with the product specications. Do not connect the UV-C device if the power supply does not full the specied regulations! You can receive further
information from your local, authorised electrician.
The power circuit for the UV-C device must be secured via a protection switch (residual current or RCD) with a rated residual current of max. 30 mA.
Prior to each intervention (installation, maintenance, etc.), the UV-C device must be disconnected from the mains!
The pressure lter incl. the UV-C device may not under any circumstances be put into use under water and must be installed next to the pond so that the risk of ooding is excluded.
The installation of the pressure lter must take place at a distance of more than 2 m and the power connection at a distance of more than 3.5 m to the pond or water basin.
It is prohibited to open the UV-C device or its associated parts if this is not expressly stipulated in these Instructions for use. This also applies for technical changes to the device.
The UV-C device features a safety switch which automatically interrupts the power supply when the device is opened. –The mains plug and all connection points must always be
kept dry. The connection cable of the UV-C device should be laid so that it is protected from damage.
The pressure lter may not be put into operation until all components and hose connections have been installed.
1
Instructions for use Ubbink BioPressure II -3000/6000/10000/18000