Datasheet

INSTALLATION COOLING REQUIREMENTS
SPECIFICATIONS
Signal span minimum 1.5 to 5V dc AC input power (1 & 2) 12 to 18V ac @ 65mA
Signal span maximum 5 to 25V dc Auxiliary output (5) 5V dc
Signal zero offset 0-30% of span Triac limiting RMS current 26A
Signal input resistance 5k ± 20% AC line voltage +/- 10% @ 50/60 Hz 25 to 230V
Manual potentiometer 2, 5 or 10k Peak single cycle surge current 250A
I
2
t for fusing (10m sec) 250A
2
s Power consumption 1.7W
Soft start time constant 0-20 seconds Max. Peak voltage 600V
Isolation voltage 2.5kV RMS Current rating 25A
Max. working temperature 65°C operational Storage temperature 0°C to 85°C
FUSING:
It is recommended to use semiconductor (fast-acting) type fuses or circuit breakers (semiconductor - MCB) for
unit protection and an appropriate fuse for unit supply (F1A). On initial power-up some loads may need an
increased factor of safety for unit and/or device protection (see SRA datasheet for further information).
CE MARKING:
This product family carries a CE marking. These phase angle controllers need a suitable remote filter. For
information see recommendation section and contact our sales desk (see Declaration of Conformity).
RECOMMENDATION
Other documents are available on request, which may be appropriate for your applications.
CODE IDENTITY DESCRIPTION
X10229 RFI Filtering recommendation - addressing EMC Directive
X10213 ITA Interaction, uses for phase angle and for burst fire control.
X10255 SRA Safety requirements - addressing the Low Voltage Directive (LVD) including:
thermal data/cooling, live parts warning, earthing requirements and fusing
recommendations.
P01.1 COS UAL conditions of sale
NOTE: It is recommended that installation and maintenance of this equipment should be done with reference to
the current edition of the I.E.T. (formally I.E.E.) regulations (BS7671) by suitably qualified/trained personnel. The
regulations contain important requirements regarding installation and safety of electrical equipment. Specific
installers should refer to local and national regulations.
ORDER CODE:
State part number: FC11AL/2 + Signal option.
Optional extras include: potentiometer, supply transformer,
heatsink assembly, heatsink compound, heatsink, filter.
Note: When ordering the filter, the current that the FC11AL/2 is to be used at will be
required.
UNITED AUTOMATION LIMITED
Southport Business Park Tel: 0044 (0) 1704 – 516500
Wight Moss Way Fax: 0044 (0) 1704 – 516501
Southport, PR8 4HQ enquiries@united-automation.com
ENGLAND www.united-automation.com
Page No. 2 of 2 Issue 7 Date 31/07/12