CE MARKING
This family carries a “CE” marking. These phase angle controllers need a suitable remote filter. For more information see
recommendations section and contact our sales desk. See Declaration of Conformity.
FUSING
It is recommended that semiconductor, fast acting type fuses or circuit breakers (Semiconductor-MCB) be used for
protection. On initial operation some loads may need an increased Factor of Safety (F of S) for unit and/or device protection.
See SRA datasheet for further information.
INSTALLATION
RECOMMENDATIONS
Other documents available on request, which may be appropriate for your application: -
CODE IDENTITY DESCRIPTION
X10229 RFI Single Phase Filter recommendations: Addressing EMC Directive
X10213 ITA Interaction: Uses for phase angle and for burst fire control.
X10255 SRA Safety requirements: Addressing the Low Voltage Directive
(LVD) including, Thermal data/cooling, Live parts warning, Earth
requirements and fusing recommendations.
P01.1 COS UAL Conditions of sale.
NOTE: It is recommended that installation and maintenance of this equipment should be done with reference to the current
edition of the I.E.T. (formally I.E.E.) regulations (BS7671) by suitably qualified/trained personnel. The regulations contain
important requirements regarding installation and safety of electrical equipment. Specific installers should refer to local and
national regulations.
UNITED AUTOMATION LIMITED
Southport Business Park Tel: 0044 (0) 1704 – 516500
Wight Moss Way Fax: 0044 (0) 1704 – 516501
Southport, PR8 4HQ enquiries@united-automation.com
ENGLAND www.united-automation.com
Page No. 2 of 2 Issue 3 Date 31/07/12
ORDER CODE: State part number: CSR ‘A’ OR ‘B’ + (load rating) and (supply voltage)
Optional extras include: knob, dial, heatsink compound.
SPECIFICATIONS UNIT CSR CSR CSR CSR CSR CSR
604A 604B 1004A 1004B 1504A
1504B
rms max. on state current A 6 6 10 10 15 15
Peak one cycle surge current A 100 100 120 120 150 150
Maximum off leakage current
MA
---------------------------------- 2 ---------------------------------
-
Minimum holding load current MA ---------------------------------- 30 --------------------------------
-
rms input voltage +/- 10% @ 50/60 Hz V ------------------------------ 110/230 ---------------------------
-
Repetitive peak voltage V --------------------------------- 400 ------------------------------
-
Total conduction phase angle (typical)
Degrees
------------------------------ 0 to 160° ---------------------------
-
Controlled phase angle (typical) Degrees
----------------------------- 30 to 160° --------------------------
--