Technical data
PD_OpManPS-4_05_us.fm
ELAU AG PacDrive PS-4 / PD-8  page 29
5.5 Cleaning
Hard-copy for correction
 Insert the SERCOS in/out cable in the corresponding cable duct, 
snap the connector into the outlet and fix the strain relief on the 
cable duct while the cable is relieved
.
 Insert the SCL connections in the corresponding cable duct, 
snap the connector into the outlet and fix the strain relief on the 
cable duct while the cable is relieved
.
Exchanging cables
 Open main switch.
 Lock out main switch.
DANGER!
High voltage!
Life hazard!
 Disconnect and connect power supply only when the plant is 
voltage-free!
 Do not insert the connectors unless both sides are dry and 
clean!
 If no ready made ELAU cables are used, make sure the 
assignment of the new cables matches the wiring diagram of the 
machine manufacturer!
 Remove cables from the PS-4 / fix them back (see Exchanging 
PacDrive PS-4).
 Remove cables from the PD-8 / fix them back (see Exchanging 
PacDrive PD-8).
 When exchanging cables, also observe the instructions of the 
machine manufacturer.
5.5  Cleaning
If installed as directed, the units are to a large extent maintenance-
free. 
To remove dust and foreign objects brought in by the cooling air 
flow, disconnect the units from the power supply, remove them and 
use dry compressed air (max. 1 bar) to blow away the pollution.