User Guide & Service Guide
USER GUIDE
u-line.com
Thermistor
Thermistor Resistance Data
Thermistors
Thermistors are used for various temperature readings. 
Thermistors provide reliable temperature readings 
using a resistance which varies based on surrounding 
temperatures. If a faulty thermistor is suspected it may be 
tested using an accurate ohmmeter.
Both thermistors in the unit are identical. If a thermistor 
is suspected of being defective, the resistance can be 
veried. Place the thermistor in an ice water bath, the 
resistance should read 16.1k Ohms +/-5% on your meter.
Thermistor connections must be kept clean. A thermistor 
connection that has become corroded can cause resistance 
values from the thermistor to change as they pass through 
a dirty connection to the board. 
It is for that reason that we apply dielectric grease to all of 
our thermistor connections. Dielectric grease will help to 
keep thermistor connections clean and dry. 
If you change a thermistor in the unit please re-apply 
dielectric grease to the connection. If you encounter 
a dirty thermistor connection, you should replace the 
thermistor and the thermistor harness.
Thermistor error information can be found in the Control 
Operations - Service section.
This unit has one thermistor.
Thermistor one (Zone):
Located along the right hand side wall. It is used to 
maintain the operating temperature within that zone.
THERMISTOR FAILURE
Zone Thermistor
If the zone thermistor in the unit fails, the unit will 
continue to cool in a backup mode (Self Preservation 
Mode) to preserve the integrity of the contents. The unit 
will otherwise operate normally.
USER GUIDE
u-line.com
Thermistor
Thermistors are used for various temperature readings. 
Thermistors provide reliable temperature readings using a 
resistance which varies based on surrounding temperatures. 
If a faulty thermistor is suspected, it may be tested using 
an accurate ohmmeter.
Thermistor connections must be kept clean. A thermistor 
connection that has become corroded can cause resistance 
values from the thermistor to change as they pass through 
a dirty connection to the board.
It is for that reason that we apply dielectric grease to all of 
our thermistor connections. Dielectric grease will help to 
keep thermistor connections clean and dry.
If you change a thermistor in the unit, please re-apply 
dielectric grease to the connection. If you encounter a dirty 
thermistor connection, you should replace the thermistor 
and the thermistor harness.
This unit has one thermistor located along the right hand 
sidewall of the ice bin. It is used to maintain the ice level in 
the bin.
Thermistor Resistance Data
* (+/
- 5%)
Thermistor
Temp (F) Temp (C)
Nominal Resistance 
(OHMS)*
-40 -40 169157
-31 -35 121795
-22 -30 88766
-13 -25 65333
-4 -20 48614
5 -15 36503
14 -10 27681
23 -5
21166
32 0 16330
41 5 12696
50 10 9951
59 15 7855
68 20 6246
77 25 5000
86 30 4029
95 35 3266
104 40 2665
113 45 2186
122 50 1803
131 55 1495
140 60 1247
149 65 1044
158 70 879
167 75 743
176 80 631
38