User Guide & Service Manual
USER GUIDE
u-line.com
Door Adjustments
Door Adjustments
DOOR ALIGNMENT AND ADJUSTMENT
Align and adjust the door if it is not level or not sealing 
properly. If the door is not sealed, the unit may not cool 
properly, or excessive frost or condensation may form in 
the interior.
NOTICE
Properly aligned, the door’s gasket should be 
rmly in contact with the cabinet all the way 
around the door (no gaps). Carefully examine the 
door’s gasket to ensure that it is rmly in contact 
with the cabinet. Also make sure the door gasket 
is not pinched on the hinge side of the door.
Do not attempt to use the door to raise or pivot 
your unit. This would put excessive stress on the 
hinge system.
Alignment and Adjustment Procedure
1.  Open door and remove gasket near the hinges.
2.  Using a T-25 Torx bit, loosen each pair of Torx head 
screws both the upper and lower hinge plates.
3.  Square and align door as necessary.
4.  Tighten Torx head screws on hinge.
5.  Reinstall gasket into the channel starting at the corner.
REVERSING THE DOOR
1.  Open door.
2.  Using T-25 Torx bit loosen screw #1 and remove screw 
#2 on top and bottom hinge. Slide and remove the 
door from the unit.
Note: One hinge includes a metal spacer. Spacer 
must be used with that hinge when reversing the 
door.
3.  Remove caps from screw heads on opposite side (2 on 
top and 2 on bottom). Using #2 Phillips bit, remove 
the 4 underlying screws. Reinstall the screws and caps 
on the opposite side.
4.  Partially install screw #1 in the outer most holes on 
top and bottom. Rotate door 180o, align hinge over 
screw #1 and slide/seat into position. Reinstall screw 
#2 on top and bottom. Tighten both screws and install 
hinge cover.
Align and adjust the door:
Align and adjust the door (see DOOR ALIGNMENT AND 
ADJUSTMENT).
T-25 Torx Screw
T-25 Torx Screw
2
1
CAUTION
!
14