User Guide & Service Manual
USER GUIDE
u-line.com
Troubleshooting Extended
Troubleshooting - Extended
SPECIFIC ERRORS AND ISSUES
The advanced diagnostic capabilities of the electronic 
controls utilized on the 1, 3, and 5 Class units allow for 
easy and thorough troubleshooting.
Navigation of the control is the key and is explained in 
the CONTROL OPERATION section of the manual, along 
with control button layout, control function descriptions, 
a service mode menu and service menu selection 
explanations.
Verication of temperature and thermistor performan
ce can 
be identied by directly viewing thermistor readings in the 
service mode.
Component failure issues can be identied through 
service mode menu #20, “Component Testing.” Individual 
components can be switched on and o to check for both 
proper function of a specic component and also delivery of 
supply voltage to the components through the relays and 
DC outputs located on the relay/power board.
Included in this section are some diagnostic tips 
and of course, if additional help is required, please 
contact the U-Line Corp, “Customer Care Facility” at 
+1.414.354.0300 for assistance.
NORMAL OPERATING SOUNDS
All models incorporate rigid foam insulated cabinets to 
provide high thermal eciency and maximum sound 
reduction for its internal working components. Despite 
this technology, your model may make sounds that are 
unfamiliar.
Normal operating sounds may be more noticeable because 
of the unit’s environment. Hard surfaces such as cabinets, 
wood, vinyl or tiled oors and paneled walls have a 
tendency to reect normal appliance operating noises.
Listed below are common refrigeration components with a 
brief description of the normal sounds they make. NOTE: 
Your product may not contain all the components listed.
• Compressor: The compressor makes a hum or pulsing
sound that may be heard when it operates.
• Evaporator: Refrigerant owing through an evaporator
may sound like boiling liquid.
• Condenser Fan: Air moving through a condenser may
be heard.
• Automatic Defrost Drain Pan: Water may be heard
dripping or running into the drain pan when the unit is
in the defrost cycle.
Solenoid Valves: An occasional clicking sound may be 
heard as solenoid valves are operated.
42