Troubleshooting Extended
MAIN CONTROL
The main control board is very robust and is rarely the 
cause of system issues. It is important to fully diagnose 
the board for any suspected failures before attempting 
to remove the board for replacement or service. Follow 
the guidelines below to fully test and diagnose the main 
control.
Power Fault
If the unit does not (or seems to not) power on, follow the 
ow chart below to help diagnose the issue. Before begin-
ning it is important to rst verify the unit is not simply set 
to sabbath mode.
Check Voltage 
At Wall Outlet
Verify Voltage At 
Main Control 
Voltage Input
Check Fuse F1
For Continuity
Replace 
Reed Switch
Replace Main
Board
Replace
Fuse
Replace
Power Cord
Alert Customer 
Of Power Failure
Is the Reed
Switch Operating
Properly?
Inspect 
Customer UI 
and Data Cable 
Connect Test Display 
Cycle Power And Check 
For Operation 
No Voltage
No Voltage
Voltage
Continuity
Operating
Not Operating
No Continuity
No
Yes
Voltage
TROUBLESHOOTING GUIDE
Concern Potential Causes Action
No Display or
Interior Lights
Unit may be in Sabbath mode •  Tap      to turn o Sabbath mode, test the door switch 
circuit
•  Unplug unit, wait 5 seconds, plug back in. If main board 
does not beep, check for 120V at black and white cables 
on power cord.
No Interior Light Light may be set to OFF
Check LED strip for power
Defective door switch
Use component testing in service mode and test light circuit, 
manually test door switch
Condensation on
exterior of unit
Is unit exposed to high humidity or high 
ambient temps?
Moisture will dissipate as ambient temp. and humidity levels 
fall. Keep exterior of unit well polished to protect surface.
No Ice
Production
Is the unit getting water? Go to component testing and turn on ll valve and verify 
120V at the valve.
Low Ice
Production
Dirty evaporator, dirty condenser, faulty 
bin thermistor
Clean the evaporator using U-Line cleaner, clean the 
condenser coil if needed, check bin thermistor reading in 
service mode.
Alert light
ashing
Check error log View errors in service mode, review error and take corrective 
action to resolve
Ice is too dense/
not dense enough
Dirty evaporator, water starvation Clean the evaporator if needed, check water supply, test 
harvest mode, adjust ice thickness
Standing Water in 
Ice Bin
Drain hose is restricted, debris in bin 
drain hole, failed drain pump failed 
dump valve
Make sure drain hose run is as straight as possible. Remove 
any kinks or tight bends, pour 1/2 gallon of water into bin to 
test drain.