User Guide & Service Manual
USER GUIDE
u-line.com
Compressor Specications
USER GUIDE
Compressor Specifications 1
u-line.com
SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE
Compressor Specifications
DANGER
!
Electrocution can cause de
ath or serious injury. 
Burns from hot or cold surfaces can cause 
serious injury. Take precautions when servicing 
this unit.
Disconnect the power source.
Do not stand in standing water when working 
around electrical appliances.
Make sure the surfaces you touch are not hot or 
frozen.
Do not touch a bare circuit board unless you are 
wearing an anti-static wrist strap that is 
grounded to an electrical ground or grounded 
water pipe.
Handle circuit boards carefully and avoid 
touching components.
To measure the start winding 
resistance, measure across 
the C and S pins.
To measure the run winding resistance, measure across 
the C and R pins.
Also check S to R and you should get the sum of the run 
and start windings.
To ensure the windings are no
t shorted, check the S and R 
to ground.
* All resistance readings are ±10%
EMX20CLC
Refrigerant R600a
Voltage 115 - 127 VAC
Frequency 60 Hz
Run Cap 12μF/165 VAC
Start Winding 6.7 Ohm at 77°F
Run Winding 12.6 Ohm at 77°F
LRA 3.7 A
FLA 0.5 A
Starting Device 8EA14C
Overload 4TM142RFBYY-53
C
S
R
OVERLOAD PROTECTOR
STARTING RELAY
CAPACITOR
RELAY COVER
ULIN_0368_A
37