quick start_guide
QUICK START GUIDE
u-line.com
Door Swing
For Integrated models that are installed adjacent to a wall,
1/2” (13 mm) clearance is recommended from wall on
hinge side to allow the door to open 90°. Allow for
additional space for any knobs or pulls installed on the
integrated panel/frame.
Stainless Steel models that are installed adjacent to a wall
require 2-1/4” (57 mm) door clearance on hinge side to
allow for door handle.
Units have a zero clearance when installed adjacent to
cabinets.
Door Adjustments
DOOR ALIGNMENT AND ADJUSTMENT
Align and adjust the door if it is not level or not sealing 
properly. If the door is not sealed, the unit may not cool 
properly, or excessive frost or condensation may form in 
the interior.
NOTICE
Properly aligned, the door’s gasket should be 
rmly in contact with the cabinet all the way 
around the door (no gaps). Carefully examine the 
door’s gasket to ensure that it is rmly in contact 
with the cabinet. Also make sure the door gasket 
is not pinched on the hinge side of the door.
Do not attempt to use the door to raise or pivot 
your unit. This would put excessive stress on the 
hinge system.
Alignment and Adjustment Procedure
1.  Open door and remove gasket near the hinges.
2.  Using a T-25 Torx bit, loosen each pair of Torx head 
screws both the upper and lower hinge plates.
3.  Square and align door as necessary.
4.  Tighten Torx head screws on hinge.
5.  Reinstall gasket into the channel starting at the corner.
T-25 Torx Screw
T-25 Torx Screw
Wall
Wall
90°
Door Swing
90°
Door Swing
Space Required
For any Knobs or Pulls
2-1/4" MIN
(57 mm MIN)
3000 Series 
Integrated
Stainless
1/2" (13 mm)
6