PROGRAMMING MENU
To access the ‘Programming’ menu press for at least 5 secs the key. If specied, the ‘PA1’ for the level 1
parameters and the ‘PA2’ for the level 2 parameters access PASSWORD will be requested (see Par. ‘PASSWORD’)
At the access, the display will show the rst parameter (“diF”). By pressing the and keys you can scroll all
parameters in the current level:
5 secs
Select the desired parameter using the and keys. Press to see the current value of the selected
parameter. Press and to change the value and then press to save it.
NOTE: It is strongly recommended that you switch the device off and on again each time the parameter conguration
is changed, in order to prevent malfunctioning of the conguration and/or ongoing timings.
PASSWORD
‘PA1’ Password:
it allows to access to the level 1 parameters. In the standard configuration the password is disabled (value = 0). To enable
it (value ≠ 0) enter the “Programming” menu by pressing the and keys, scroll the parameters until “PS1” label
is displayed, press the key to display the current value, change it by using the and keys and then press the
key to save it. If the password is already enabled, you will be required to enter it to access the ‘Programming’ menu.
To enter it:
‘PA2’ Password:
it allows to access to the level 2 parameters. In the standard configuration the password is enabled (valore 0). To change
its value follow the steps like for ‘PA1’ and change the ‘PS2’ parameter value. The visibility of the ‘PA2’ label will be:
1) If PA1 and PA2 ≠ 0: By pressing the key for more than 5 seconds, “PA1” and “PA2” labels will be displayed at the
same level and it will be possible to access either the level 1 or the level 2 parameters.
2) Otherwise: The ‘PA2’ password is present between the level 1 parameters. If ‘PA2’ is enabled, you will be
required to enter it to access the level 2. To enter it follow the steps described for the PA1’ password
If the password is incorrect, the instruments display the PA1/PA2 label and you will have to repeat the entry procedure.