User Guide & Service Manual
USER GUIDE
 Control Operation - Service 3
u-line.com
SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE
To access All Errors follow the steps below.
1. Press   to select “All Errors”.
2. Press .
3. Press   and   to scroll through available 
information.
To clear the error log press   to select “Clear Errors” and 
press to confirm.
To exit the Actual Temps menu press   to select “Return 
to Menu” and press   to confirm.
Relay Status
Relay status displays the current state of each relay. While 
all available relays are displayed, only a portion are used.
NOTE: The Cond (Condenser Fan) will switch state with 
the compressor relay, however the condenser fan is 
actually powered through a DC output. Condenser fan 
status can be viewed through the “Output” service menu 
option.
To access Relay Status
1. Use   to select “Relay Status”.
2. Press .
3. Press   and   to scroll through available 
information.
To exit the Relay Status simply press   to exit.
Relay Toggle
Relay toggle is used to manually switch the state of each 
relay to test for proper operation. In addition to the AC 
relays, DC switches may also be toggled. Relay toggle can 
also be used to force the unit into a particular state. 
To access Relay Toggle
4. Press   to select “Relay Toggle”.
ID Description Availability 
Mull Mullion Heater Drawer Models
N/A N/A N/A
LVLV Left (top) valve All Models
RVLV Right (bottom) valve All Models
Cond Condenser Fan All Models
Comp Compressor All Models
Up
Select
Down
RETURN TO MENU
RELAY STATUS
MULL COND DEF  LVLV
OFF OFF OFF OFF
ID Description Voltage
Mull Mullion Heater (Drawers) AC
N/A N/A N/A
LVLV Left (top) valve AC
RVLV Right (bottom) valve AC
Cond Condenser fan (Not Used) AC
Comp Compressor AC
Fan 1 Left/Top Condenser Fan 
(Excludes ZWC)
DC
Fan 2 Condenser Fan DC
Fan 3 Right/Bottom Evaporator Fan
(Excludes ZWC)
DC
Light 1 Left (top) light DC
Light 2 Right (bottom) light DC
Up
Select
Down
RETURN TO MENU
RELAY TOGGLE
MULL OFF
COND OFF
48