User Guide & Service Manual
USER GUIDE
 Anti-Tip Bracket 1
u-line.com
SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE
Anti-Tip Bracket
CAUTION
!
The anti-tip bracket must be installed to prevent 
the unit from tipping when doors are fully 
opened or excess weight is placed on the front of 
the unit.
The anti-tip brackets have multiple mounting options. 
Mounting will depend on your particular cabinet 
configuration. Locate 6 #8x5/8" screws included with your 
unit.
TOP MOUNT
For ease of installation the anti-tip brackets are 
pre-installed in the top mount position. 
1. Completely slide the unit into its position in the 
opening. Be certain unit height is properly adjusted. 
(See GENERAL INSTALLATION).
2. Open both doors completely. Make certain doors clear 
surrounding cabinetry.
3. Using a 3/32" (2.50 mm) drill bit, drill 6 pilot holes 
(3 for each bracket) 5/8" (16 mm) deep into bottom of 
countertop. Use the anti-tip brackets as a template.
4. Install 6 #8x5/8" screws into the plate using a #2 
Phillips head screwdriver.
SIDE MOUNT
Side mount position is used when you are unable to mount 
the brackets to the underside of your countertop.
1. Remove the pre-installed anti-tip brackets from the top 
mount position and align to the side mounting holes on 
the hinge side of your model as shown.
2. Reinstall 2 screws into each anti-tip bracket, mounting 
the bracket to your unit. 
3. Completely slide the unit into its position in the 
opening. Be certain unit height is properly adjusted. 
(See GENERAL INSTALLATION).
4. Open both doors completely to gain access to the anti-
tip brackets. Make certain doors clear surrounding 
cabinetry.
5. Using a 3/32" (2.50 mm) drill bit, drill 6 pilot holes (3 
for each bracket) 5/8" (16 mm) deep into cabinetry 
frame using the anti-tip brackets as a template.
6. Install 6 #8x5/8" screws into the plate using a #2 
Phillips head screwdriver.
Left Hinged Cabinet
Right Hinged Cabinet
11