REPLACEMENT PARTS: Use only genuine U-Line replacement parts. The use of non U-Line parts 
can reduce ice rate, cause water to overflow from ice maker mold, damage the unit, and may void 
the warranty.
IF UNIT HAS P-60 PUMP
Cause
a. Drain tube kinked or obstructed.
b. Bad pump. Diagnose by bypassing the pump. 
Pull both pink wires from control board and 
jump the two terminals together. If unit starts 
up, then the pump is bad.
c. Open wire in wiring harness.
16. Water leak under unit
Cause
a. Incoming water supply line leaking.
b. Fill tube leaking.
c. Bin spout is cracked or mis-formed.
17. Water in ice bin
Cause
a. Bin drain kinked or restricted.
b. External drain is restricted.
c. Bad pump.
18. Water will not stop filling
Cause
a. Water solenoid stuck in open position.
b. Open relay on control board.
NOTE: A defective relay on control board 
would cause both the water valve and reversing
valve to stay open, therefore, this failure would
not allow the unit to freeze.
19. Unit noisy
Cause
a. Fan motor not secured to bracket.
b. Fan blade bent.
c. Vibration from refrigerant lines.
d. Obstruction in fan blade.
Remedy
a. Clear the tubing. If water cannot drain from 
pump, unit will shut down due to safety 
design of pump.
b. Change pump. Jumping the two terminals on 
control board together with a jumper wire will
eliminate pump from the circuit.
c. Trace defective wire and repair or 
replace parts accordingly.
Remedy
a. Make sure brass connection is screwed tight to
valve and threaded correctly.
b. Tighten fill tube connection to water line.
c. Unit not repairable. Contact U-Line tech line 
for assistance.
Remedy
a. Clear drain of obstruction or kink.
b. Clear restriction.
c. Replace pump.
Remedy
a. Replace water valve.
b. Replace control board.
Remedy
a. Tighten motor.
b. Realign or replace blade.
c. Secure tubing.
d. Remove obstruction.