QUICK START GUIDE Modular 3000 Series • 3018 CLR • 115 V / 60 Hz
QUICK START GUIDE u-line.com WELCOME TO U-LINE Congratulations on your U-Line purchase. Your product comes from a company with over five decades and three generations of premium modular ice making, refrigeration, and wine preservation experience. U-Line continues to be the American leader, delivering versatility and flexibility for multiple applications including residential, light commercial, outdoor and marine use.
QUICK START GUIDE Contents 1 Model List 2 Safety and Warning 2 Environmental Requirements 3 Electrical 3 Water Hookup 5 Drain 7 Door Swing 8 General Installation 8 Integrated Panel Installation 10 Control Quick Guide 10 First Use 10 Ice 12 Sabbath Mode 12 Warranty u-line.
QUICK START GUIDE u-line.com Model List This guide provides the basics to get you started. Looking for more information? Visit u-line.com to view detailed User Guides for all U-Line products. Clear Ice Machines U-3018CLRS-00B U-3018CLRS-40B U-3018CLRINT-00B U-3018CLRINT-40B Visit http://www.u-line.com/product-literature/userguides or scan this QR code to view all user guides online.
QUICK START GUIDE u-line.com Safety and Warning Environmental Requirements NOTICE This model is intended for indoor/interior applications only and is not to be used in installations that are open/ Please read all instructions before installing, exposed to natural elements. operating, or servicing the appliance. This unit is designed to operate between 50°F (10°C) and Use this appliance for its intended purpose only and follow 100°F (38°C).
QUICK START GUIDE u-line.com Electrical Water Hookup PREPARE PLUMBING ! WARNING Please use the braided stainless steel water supply line which comes attached. The water line is fitted with a SHOCK HAZARD — Electrical Grounding standard 1/4" (6.35 mm) compression fitting. Required. Never attempt to repair or perform maintenance on the unit until the electricity has been disconnected.
QUICK START GUIDE u-line.com 4. Turn on water and check for leaks. ! CAUTION 5. Route water supply line in cable clamp and secure with Do not use any plastic water supply line. The line screw. is under pressure at all times. Plastic may crack or rupture with age and cause damage to your home. Do not use tape or joint compound when attaching a braided flexible water supply line that includes a rubber gasket. The gasket provides an adequate seal – other materials could cause blockage of the valve.
QUICK START GUIDE u-line.com Drain GRAVITY DRAIN Model numbers including “-00” or “-07” do not include a factory installed drain pump. Normal Proper Drain Model numbers including “-40” or “-47” include a factory installed drain pump. With Trap Poor Drainage, Water Will Back Up DRAIN CONNECTION ! CAUTION With Trap and Vent Proper Drain If your U-Line unit did not come with a factory installed drain pump you must use a gravity A gravity drain may be used if: style drain connection.
QUICK START GUIDE u-line.com FACTORY INSTALLED DRAIN PUMP Y-Branch Tailpiece P60 Pump Required If your drain line will run up to a stand pipe, disposal or Air Gap (Optional Hook-Up) spigot assembly, or does not otherwise meet the requirements for a gravity drain, you may have ordered a pre-installed U-Line P60 drain pump. Waste If you need to install a P60 drain pump into your unit, see 6KXW 2ɞ Valve DRAIN PUMP section in the User Manual.
QUICK START GUIDE u-line.com Door Swing Wall For Integrated models that are installed adjacent to a wall, 1/4" (6 mm) 1/4" (6 mm) clearance is recommended from wall on hinge side to allow the door to open 90°. Allow for additional space for any knobs or pulls installed on the integrated panel/frame. Stainless Steel models that are installed adjacent to a wall require 2-1/4" (57 mm) door clearance on hinge side to allow for door handle.
QUICK START GUIDE u-line.com General Installation INSTALLATION 1. Plug in the power/electrical cord. 1. Use a level to confirm the unit is level. Level 2. Gently push the unit into position. Be careful not to should be placed along top edge and side entangle the cord or water and drain lines. 1 edge as shown. 3. Re-check the leveling, from front to back and side to side. Make any necessary adjustments. The unit’s top 2.
QUICK START GUIDE u-line.com 10.Ensure the screws sit flush against the bottom of the NOTICE channel. Due to differences in floor construction or surrounding cabinetry, the panel may not sit flush with the top of the door. 6. Secure integrated panel to door using Bar Clamp Integrated Panel Integrated Panel clamps. A robust tape may also be 11.Remove clamps from door. used. U-Line recommends the use of bar clamps to secure the panel to the door.
QUICK START GUIDE u-line.
QUICK START GUIDE u-line.com The ice cube thickness is factory set for best overall performance. The factory setting “0” is designed to THINNER BRIDGE THICKER BRIDGE maintain an ice bridge of approximately 1/16" to 1/8" DEEPER DIMPLE (1.6 mm to 3.2 mm) under normal conditions, resulting in SHALLOWER DIMPLE a dimple of approximately 1/4" to 1/2" (6.4 mm to 12.7 mm) in depth. A fuller cube with less of a dimple results in a thicker ice bridge.
QUICK START GUIDE u-line.com Warranty L U-LINE CORPORATION LIMITED WARRANTY Sabbath Mode 1. U-Line Corporation (“U-Line”) warrants each U-Line product to be free from defects in materials and 1 2 3 4 5 6 workmanship for a period of one year (two years on 7 Modular 3000 Series) from the date of installation.
QUICK START GUIDE u-line.com warranty does not apply to cosmetic damages. A proof 1-800-779-2547 or the dealer from whom you of purchase may be required. purchased the product. In no event shall such notification be received later than 30 days after the expiration of the applicable warranty period. U-Line 4.