User Guide 2
USER GUIDE
Door Adjustments 1
u-line.com
SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE
Door Adjustments
DOOR ALIGNMENT AND ADJUSTMENT
Align and adjust the door if it is not level or is not sealing 
properly. If the door is not sealed, the unit may not cool 
properly, or excessive frost or condensation may form in 
the interior.
NOTICE
Properly aligned, the door’s gasket should be 
firmly in contact with the cabinet all the way 
around the door (no gaps). Carefully examine 
the door’s gasket to ensure that it is firmly in 
contact with the cabinet. Also make sure the 
door gasket is not pinched on the hinge side of 
the door.
CAUTION
!
Do not attempt to use the door to raise or pivot 
your unit. This would put excessive stress on the 
hinge system.
Alignment and Adjustment Procedure
1. Open door and remove gasket near the hinges.
2. Using a T-25 Torx Bit, loosen each pair of Torx head 
screws on both the upper and lower hinge plates.
3. Square and align door as necessary.
4. Tighten Torx head screws on hinge.
5. Reinstall gasket into the channel starting at the corner.
REVERSING THE DOOR
1. Open door.
2. Remove top hinge cover by lifting top and bottom flaps 
and slide inwards. Repeat on bottom hinge.
T-25 Torx Screw
T-25 Torx Screw